2.4 Zeroing
CAUTION:
ALWAYS
perform zeroing if the ballistic turret has been changed.
CAUTION:
ALWAYS
perform zeroing with the ballistic turret set to the "
1
" setting
and the wind correction turret set to the "
0
" setting.
CAUTION:
DO NOT
continue to adjust windage and elevation screws if you
encounter resistance.
Zeroing is performed by adjusting the torx T10 adjustment screw positioned in the
center of the ballistic turret and the wind correction turret. See Fig. 4.
To perform zeroing:
a
Open lens covers and adjust the intensity to a comfortable setting for the red dot to
contrast against the target.
b
Set the ballistic turret to the ”
1
” setting (see ”
A
” in Fig. 4).
c
Set the wind correction turret to the ”
0
” setting.
d
Fire at least three shots at the zeroing target and evaluate Points Of Impact (POI).
e
Elevation adjustments (see ”
B
” in Fig. 4):
•
Turn elevation adjustment screw counterclockwise to move POI up (
UP
).
•
Turn elevation adjustment screw clockwise to move POI down.
f
Windage adjustments (see ”
C
” in Fig. 4):
•
Turn windage adjustment screw counterclockwise to move POI to the right (
R
).
•
Turn windage screw clockwise to move POI to the left.
NOTE:
Each click of the adjustment screws corresponds to 10 mm movement of
POI at 100 m (20 mm at 200 m).
Содержание CompM5b
Страница 1: ...CompM5b User manual ...
Страница 2: ... 2020 2021 Aimpoint AB 15722 2 WWW AIMPOINT COM ...
Страница 9: ...A B Fig 3 Remove install ballistic turrets ...
Страница 11: ...A B C Fig 4 Zeroing ...
Страница 15: ...A B C Fig 6 Preparations ...
Страница 17: ...Fig 7 Create custom settings A B C ...
Страница 19: ......