AiM InfoTech 

K-M-P - GCU2 

Release 1.00 

 

 

 

 

Содержание K-M-P - GCU2

Страница 1: ...AiM InfoTech K M P GCU2 Release 1 00 ...

Страница 2: ...odule is set with the following default parameters Refer to the manufacturer for additional details on the configuration procedure Baudrate 1Mbit s 1000kbit s CAN ID 1 2000 0x7D0 CAN ID 2 2001 0x7D1 CAN ID 3 2002 0x7D2 CAN ID 4 2003 0x7D3 CAN ID 5 2004 0x7D4 Please note In case this module is going to be used with different parameters the user can set up a custom driver from the CAN Protocols sect...

Страница 3: ...07 connector right picture below located on the universal loom or through the main 37 way connector of the GCU 2 In this case the mating part AS614 35SN is pictured below left and the connection table for both options follows 35 pin Deutsch Pin nr 2 pin Deutsch Pin nr Function AiM wire label optional harness 10 1 CAN High CAN2 11 2 CAN Low CAN2 ...

Страница 4: ...he AiM device connected to this module enable the CAN Bus 120 Ohm Resistor 4 KMP GCU2 protocol Channels received by AiM loggers configured with KMP GCU2 protocol are CHANNEL NAME FUNCTION GEAR POT Gear potentiometer voltage SYS PRESSURE System pressure COMP TEMP Compressor temperature ERROR CODE CNT Error code counter ERR CODES Error code UP Upshift valve DOWN Downshift valve BLIP Blip valve IGN C...

Страница 5: ...US Shift status AUTOCALIB ST Autocalibrationstatus CLUTCH FLAG Clutch active CLUTCH PRESS Clutch pressure AUTOSHIFT FLAG Autoshift flag SHIFT LIGHT Shift light active VEH SPEED Vehicle speed CALC GEAR RATIO Calculated gear ratio SHF CHK FLAG Shift check flag REVERSE Reverse switch active BLIP LEV Blip level variable blip CAN OK CAN bus ok check DEBUG MODE Debug mode active ...