62
The
soft-key indicates that there are too many options to show all at once so press this key to
show more. In this case there is one more list of types.
One more press of the
soft-key will show the first list again. Select the Sync type required by
pressing the appropriate key then press the
soft-key to return to the top level Sync menu or
press the Utility key to exit the Utility menus.
The available Sync types are explained below:
Auto:
Automatically sets the most relevant Sync output for the instrument set-up. The chosen
type is shown in brackets.
Carrier Sync:
A square wave at the same frequency and duty as the carrier waveform.
Available for all waveforms except noise.
Modulation Sync:
A square-wave at the same frequency as the internal modulation waveform
with a duty of 50%. Not available for external modulation.
Sweep Sync:
Outputs the sweep trigger and sweep marker signals.
Burst Sync:
A square wave coincident with a burst output.
Trigger:
A buffered version of the Trigger signal.
Output Type
Pressing the
Type
soft-key on the Output menu will alternate between
Normal
and
Inverse
.
Inverse
will invert the carrier waveform at the MAIN OUT connector. This is shown by
Inv
in
the
OUT
field of the Parameters Box and the carrier waveform in the Graph Box will be inverted.
Inversion is also possible using the +/– key as described in the Continuous Carrier Waveform
Operation section.
Load
Pressing the
Load
soft-key will show the current load value in the Edit Box.