![Aim-TTI TG2511A Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/aim-tti/tg2511a/tg2511a_instruction-manual_2871846059.webp)
58
It is possible to set any combination of Frequency, Amplitude and Output coupling. When a
parameter is coupled it may be changed on either channel and the other channel will also change.
To select frequency coupling press the
Freq
soft-key. This will show the frequency tracking
options.
Use the
On/Off
soft-key to enable of disable frequency coupling. Note that
*
is shown next to
FRQ in the Parameters box.to indicate that the parameters are coupled
To select the type of frequency coupling press the
Type
soft-key.
There are two types of frequency coupling available
Offset CH2 Freq – CH1 Freq
and
Ratio CH2 Freq / CH1 Freq
. Offset applies a fixed difference between the channels which
is equal to Channel 2 frequency – Channel 1 frequency. Ratio sets the frequencies so that Ratio is
equal to Channel 2 frequency divided by Channel 1 frequency.
The selected type of frequency coupling will show either an
Offset
soft-key or a
Ratio
soft-
key to allow the respective value to be set. These numeric values may be changed in either of the
ways detailed in General: Numeric Editing
When entering Tracking or Coupling modes the instrument will automatically phase align the
channels. The phases may become misaligned by subsequent parameter changes. This is most
likely to occur when changing frequency while in Coupled-Frequency-Offset mode.To realign the
phase press
the
Align
soft-key
from the carrier menu
.