2
Specification
Input Voltage:
Factory set to 230V, 115V or 100V; 50Hz or 60Hz.
Installation Category II.
Supply Tolerances:
230V setting : 198V – 253V
115V setting: 99V – 127V
100V setting: 90V – 110V
50Hz setting: ± 0·5Hz
60Hz setting: ± 0·6Hz
Output Voltage:
Tracks the amplitude of the fundamental of the input voltage. A variable
voltage input may be used to adjust the output voltage to within the limits
specified by EN61000–3–2.
Output Distortion:
Dependent on the purity of the input but will generally meet the requirements
of EN61000–3–2.
Output Current:
Maximum continuous output current is 4·4A.
Maximum peak current (repetitive or surge) is 10A
Output Power:
Maximum output power is input voltage x 4·4 VA
Input Connection:
IEC connector; front panel switch.
Output Connection:
U.K., Schuko, or other national outlet sockets. Load power switch can be set
to DIRECT or CORRECTED for ‘A–B’ comparisons.
Protection:
Thermal trip automatically diverts load to a DIRECT connection in the event of
thermal overload.
Operating Range:
+5
°
C to +35
°
C at full rated output; 20% to 80% RH (non-condensing).
Storage Range:
–40
°
C to +70
°
C
Environmental:
Indoor use at altitudes to 2000m, Pollution Degree 2.
Safety:
Complies with EN61010–1
EMC:
Complies with EN61326-1.
Size:
307 x 105 x 225 mm (W x H x D)
Weight:
5 kg.
Telemeter Electronic GmbH | Joseph-Gaensler-Str. 10 | Phone +49 906 70693-0 | Fax +49 906 70693-50 | www.telemeter.info