Aigis Mechtronics MLAC Series Скачать руководство пользователя страница 5

Dip switch locations.

See details for 

switch positions.

Phase adjust pot
on power board.
Tilt camera board
for clear access.

9

 

1

1
2
3
4
5
6
7
8

Off
On

Off

AWB

GAM

AGC
ESC

BLC

FL

AE

Not Used

Note:

is factory set up

1. AWB: Automatic White Balance Function
 

Off - Holds white balance

 

        at current setting

 

On - Continuous white balance

2. GAM: Gamma Function
 

Off - g = 1.0

 

On - g = 0.6

3. AGC: Automatic  Gain  Control
 

Off - AGC function is Off

 

On - AGC function is On

4. ESC: Electronic Shutter Control
 

Not applicable for Auto Iris

5. BLC: Backlight Compensation
 

Off - BLC function is Off

 

On - BLC function is On

6. FL: Flicker Less
 

Not Applicable  for Auto  Iris

7. AE: Auto Iris - Electronic Iris Selection
 

Factory default - On

2

3

4

5

6

7

8

5. CAMERA/LENS SETTINGS

The camera module has various settings for any additonal adjustments that
may be required. See Figure 4 for adjustment locations.

5.1 Dip Switches

The following chart diagrams the selectable dip switches and their respective
functions:

Figure 4  Varifocal Camera Adjustments

Figure 5  Layout of Dip Switches

5.2 Phase Adjust

The phase adjust control is located on the power board next to power cable
connections (see Figure 4).To adjust phase, use a small screwdriver to rotate
the control (blue block with yellow screw hole) until the picture is synchronized
with other cameras in the system.

8

Top Bracket

Install camera bracket
between top bracket and nut.

Nut; loosen but
do not remove.

Position camera as desired and 

tighten fasteners securely. 

Do not overtighten!

Tilt adjustment; 
thumb-nut (two places).

Rotation adjustment;
thumbscrew (two places).

Vertical adjustment;

Phillips screw & nut

(two places).

Pan adjustment;

small Phillips screw

(two places).

Forward/back adjustment;

use 10 mm wrench.

4. Decide which conduit hole will be used and plug remaining openings using

the 2 plugs provided in the hardware kit.The conduit plug on top of the unit
may be secured by tightening the set screw at the back of the rear cover.
This must be done before the back cover is secured to the wall. Use a 2.5
mm Hex Key (not supplied).

5. Drill hole for conduit and run wiring.

6. Use 6 mm (1/4-inch) bolts with appropriate anchors for the type of wall

construction.

WARNING: The MLAC Corner Unit can withstand 300 lb of static 

downward load if appropriate bolts and anchors are employed.

7. Remove the camera module from packaging.

8. Loosen the nut located on the back plate approximately 6 turns without

removing, and insert camera bracket between the nut and retaining bracket
(see Figure 2).

Figure 2  Rear Plate Exploded View

9. Tighten nut securely.

10. Adjustability: Camera/lens is fully adjustable. See Figure 3 for adjustment

points.

Figure 3  Camera Position Adjustment Points

11. Replace cover and secure using the supplied tamper-resistant screw (See

Figure 1).

Содержание MLAC Series

Страница 1: ...12 4 20 3 80 99 31 3 910 Pos t nt ch MINILINE ALUMINUM CORNER HOUSINGS MLAC Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S...

Страница 2: ...CTROCUTION NE PAS OUVRIR LE BO TIER IL N Y A PAS DE PI CES REMPLA ABLES L INT RIEUR POUR TOUTE R VISION S ADRESSER UN TECH NICIEN SP CIALIS 3 This label may appear on the bottom of the unit due to spa...

Страница 3: ...IA HUMEDAD PRECAUCION PARA REDUCIR EL RIESGO DE CHOQUE EL CTRICO FAVOR NO ABRIR LA CUBIERTA ESTE EQUIPO NO CONSTA DE PIEZAS O PARTES QUE REQUIEREN SERVICIO O MANTENIMIENTO PARA REPARACIONES FAVOR REFE...

Страница 4: ...n a commercial environment This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference...

Страница 5: ...ized with other cameras in the system 8 Top Bracket Install camera bracket between top bracket and nut Nut loosen but do not remove Position camera as desired and tighten fasteners securely Do not ove...

Страница 6: ...FIBER CABLE CONNECT CAMERA AND FIBER MODULE TO THE SAME 24VAC POWER SOURCE SUGGESTED CABLE ROUTING FIBER OPTIC CONNECTION NOTE POSITION OF DIP SWITCHES FOR CAMERA UP POSITION 6 FIBER OPTIC CONNECTION...

Страница 7: ...2002 Aigis Mechtronics 1124 Louise Road Winston Salem NC 27107 5450 Tel 336 785 7740 Fax 336 785 7744 100 0038 001 AIG 10 02 Printed in U S A Data subject to change without notice...

Отзывы: