IMPORTANT SAFEGUARDS

1.

Read Instructions - All the safety and operating
instructions should be read before the unit is operated.

2.

Retain Instructions - The safety and operating instructions
should be retained for future reference.

3.

Heed Warnings - All warnings on the unit and in the
operating instructions should be adhered to.

4.

Follow Instructions - All operating and use instructions
should be followed.

5.

Cleaning - Unplug the unit from the outlet before
cleaning. Do not use liquid cleaners or aerosol cleaners.
Use a damp cloth for cleaning.

6.

Attachments - Do not use attachments not
recommended by the product manufacturer as they may
cause hazards.

7.

Accessories - Do not place this unit on an unstable stand,
tripod, bracket, or mount. The unit may fall, causing
serious injury to a person and serious damage to the unit.
Use only with a stand, tripod, bracket, or mount
recommended by the manufacturer, or sold with the
product. Any mounting of the unit should follow the
manufacturer's instructions, and should use a mounting
accessory recommended by the manufacturer.

An appliance and cart combination should be moved
with care. Quick stops, excessive force, and uneven
surfaces may cause the appliance and cart combination
to overturn.

8.

Ventilation - Openings in the enclosure, if any, are
provided for ventilation and to ensure reliable operation
of the unit and to protect it from overheating. These
openings must not be blocked or covered. This unit
should not be placed in a built-in installation unless proper
ventilation is provided or the manufacturer's instructions
have been adhered to.

9.

Power Sources - This unit should be operated only from
the type of power source indicated on the marking label.
If you are not sure of the type of power supply you plan
to use, consult your appliance dealer or local power
company. For units intended to operate from battery
power, or other sources, refer to the operating
instructions.

10. Grounding or Polarization - This unit may be equipped

with a polarized alternating-current line plug (a plug
having one blade wider than the other). This plug will fit
into the power outlet only one way. This is a safety
feature. If you are unable to insert the plug fully into the
outlet, try reversing the plug. If the plug should still fail to
fit, contact your electrician to replace your obsolete
outlet. Do not defeat the safety purpose of the polarized
plug.
Alternately, this unit may be equipped with a 3-wire
grounding-type plug, a plug having a third (grounding) pin.
This plug will only fit into a grounding-type power outlet.
This is a safety feature. If you are unable to insert the plug
into the outlet, contact your electrician to replace your
obsolete outlet. Do not defeat the safety purpose of the
grounding-type plug.

11. Power-Cord Protection - Power-supply cords should be

routed so that they are not likely to be walked on or
pinched by items placed upon or against them, paying
particular attention to cords and plugs, convenience
receptacles, and the point where they exit from the
appliance.

12. Power Lines - An outdoor system should not be located

in the vicinity of overhead power lines or other electric
light or power circuits, or where it can fall into such
power lines or circuits. When installing an outdoor
system, extreme care should be taken to keep from
touching such power lines or circuits as contact with
them might be fatal. U.S.A. models only - refer to the
National Electrical Code Article 820 regarding installation
of CATV systems.

13. Overloading - Do not overload outlets and extension

cords as this can result in a risk of fire or electric shock.

14. Object and Liquid Entry - Never push objects of any kind

into this unit through openings as they may touch
dangerous voltage points or short-out parts that could
result in a fire or electric shock. Never spill liquid of any
kind on the unit.

15. Servicing - Do not attempt to service this unit yourself as

opening or removing covers may expose you to
dangerous voltage or other hazards. Refer all servicing to
qualified service personnel.

16. Damage Requiring Service - Unplug the unit from the

outlet and refer servicing to qualified service personnel
under the following conditions:
a.

When the power-supply cord or plug is damaged.

b.

If liquid has been spilled, or objects have fallen into
the unit.

c.

If the unit has been exposed to rain or water.

d.

If the unit does not operate normally by following the
operating instructions. Adjust only those controls
that are covered by the operating instructions, as an
improper adjustment of other controls may result in
damage and will often require extensive work by a
qualified technician to restore the unit to its normal
operation.

e.

If the unit has been dropped or the cabinet has been
damaged.

f.

When the unit exhibits a distinct change in
performance--this indicates a need for service.

17. Replacement Parts - When replacement parts are

required, be sure the service technician has used
replacement parts specified by the manufacturer or have
the same characteristics as the original part.
Unauthorized substitutions may result in fire, electric
shock or other hazards.

18. Safety Check - Upon completion of any service or repairs

to this unit, ask the service technician to perform safety
checks to determine that the unit is in proper operating
condition.

19. Coax Grounding - If an outside cable system is connected

to the unit, be sure the cable system is grounded. U.S.A.
models only--Section 810 of the National Electrical Code,
ANSI/NFPA No.70-1981, provides information with
respect to proper grounding of the mount and supporting
structure, grounding of the coax to a discharge unit, size
of grounding conductors, location of discharge unit,
connection to grounding electrodes, and requirements
for the grounding electrode.

20. Lightning - For added protection of this unit during a

lightning storm, or when it is left unattended and unused
for long periods of time, unplug it from the wall outlet
and disconnect the cable system. This will prevent
damage to the unit due to lightning and power-line
surges.

Содержание HS9383S-2HP

Страница 1: ...Stainless Steel Pressurized Housing HS9383S 2HP HS9383S P I N S T A L L A T I O N A N D O P E R A T I N G I N S T R U C T I O N S W W W A I G I S M E C H C O M...

Страница 2: ...ular attention to cords and plugs convenience receptacles and the point where they exit from the appliance 12 Power Lines An outdoor system should not be located in the vicinity of overhead power line...

Страница 3: ...his equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However the...

Страница 4: ...ety relief valve is mounted on the rear cap along with the Schrader valve The purpose of the relief valve is to provide a safety pressure blow off should internal pressure exceed 140 kPa 20 PSIG at on...

Страница 5: ...ools Required Min 3 16 x 4 inch Flat blade screwdriver 5 32 inch or 4 mm hex wrench Wire Stripper Crimper Tool 5 3 Cradle Removal Figure 1 Remove Retaining Ring Use a Flatblade Screwdriver 1 Remove th...

Страница 6: ...ns to extend outward when zooming Secure both the camera and the lens to the cradle with the 1 4 20 BHCS and appropriate plastic spacer 4 Connect the camera into the housing 5 Attach camera power sour...

Страница 7: ...ring diagram below 4 Slide the white seal sleeve down against the back of the the wire harness plug 5 Apply electrical tape around the plug and the seal sleeve to create a form to pour the potting com...

Страница 8: ...ing is in place at the bottom of the threads on the rear cap of the housing 2 Insert the wire harness plug into the back of the housing 1 2 1 3 1 4 1 5 1 6 1 1 1 2 1 3 1 4 1 5 1 6 1 1 1 2 1 3 1 6 3 Sl...

Страница 9: ...9 1 2 1 3 1 4 1 5 1 6 1 1 4 In a chris cross pattern using the 5 32 inch hex wrench tighten down the three BHC SS screws in the back of the coupler Tighten all three screws...

Страница 10: ...gth of at least 200 kg 450 lb 3 Locate the four holes or stud locations using the flange as a template four holes equally spaced on a 69 9 mm 2 3 4 in bolt circle 4 Install the mount using bolts or st...

Страница 11: ...11 mm in 350 2 13 79 203 2 8 00 302 6 11 91 3 75 95 3 88 9 3 50 8 9 35 mm in 304 8 12 0 14 00 5 832 71 9 355 6 6 DIMENSIONAL OUTLINES...

Страница 12: ...2005 Aigis Mechtronics 1124 Louise Road Winston Salem NC 27107 5450 Tel 336 785 7740 Fax 336 785 7744 Data subject to change without notice 100 0193 001 AIG 02 07 Draft Printed in U S A...