Doc No. FM0460 issue K Page 1
169MHz Telecare Devices
Temperature Extreme Sensor
__________________________________________________________________________________________________________
•
Compatible with Reach at-home alarms, Advent xt warden call,
Altec Response and Touchsafe Pro Nursecall systems
•
Solid state temperature sensing element
•
Lower alarm temperature: 5
o
C +/- 2.5
o
C for 30/60 minutes
•
Upper alarm temperature: 30
o
C +/- 2.5
o
C for 5/10 minutes
•
Rate of rise alarm temperature: 8
o
C per minute
•
User replaceable 3.6V AA Lithium battery
•
Low battery warning
•
Test button
•
Dimensions: 84 x 84 x 36 mm (HxWxD)
•
Weight: 102 grams
•
Product Code: ZXT426
What are Temperature Extreme Sensors used for?
The temperature extreme sensor will provide early warning of extreme low or high household temperatures which could result in
the occupier suffering hypothermia or dehydration. In addition, the building will also be protected against burst pipes or potential
fire hazards.
Where should Temperature Extreme Sensors be fitted?
The temperature extreme sensor should be fitted in the hallway or living room.
It should be wall mounted at around 1.4 metres above floor level and away from any draughts or heat sources.
Typical Tools Required
A drill and screwdriver are not required if the self adhesive pad is used.
Always make sure the correct drill bits and screwdrivers are used.
Installation
–
Using Screw Fixings
1.
Remove the top by pulling apart from the back section.
2.
Drill the back section as required and fix to the wall using
the screws & plugs provided.
3.
Set the DIL switches & links, fit the battery and test as
described on the following page before refitting the top section.
Installation
–
Using Self Adhesive Pads
1. Remove the top by pulling apart from the back section.
2.
Select the best location where the wall is clean, dry and even.
3.
Stick the adhesive pad to the rear face of the back section and
press firmly to the wall ensuring it is stuck securely.
4.
Set the DIL switches and links, fit the battery and test as
described on the following page before refitting the top.
PULL APART
TO REMOVE
TOP
SECTION
FIX
BACK
SECTION TO
WALL
Tynetec and Aidcall are business units of Legrand Electric Ltd
Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth
Northumberland, NE24 5TF. Tel:
01670 352 371
Email:
Web
:
www.tynetec.co.uk