background image

Doc No. FM0460 issue K Page 1  

169MHz Telecare Devices 

Temperature Extreme Sensor 

 

__________________________________________________________________________________________________________ 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatible with Reach at-home alarms, Advent xt warden call,  
Altec Response and Touchsafe Pro Nursecall systems 

 

Solid state temperature sensing element 

 

Lower alarm temperature: 5

o

C +/- 2.5

o

C for 30/60 minutes 

 

Upper alarm temperature: 30

o

C +/- 2.5

o

C for 5/10 minutes 

 

Rate of rise alarm temperature: 8

o

C per minute 

 

User replaceable 3.6V AA Lithium battery 

 

Low battery warning 

 

Test button 

 

Dimensions: 84 x 84 x 36 mm (HxWxD) 

 

Weight: 102 grams 

 

Product Code: ZXT426 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What are Temperature Extreme Sensors used for? 

 

The temperature extreme sensor will provide early warning of extreme low or high household temperatures which could result in 
the occupier suffering hypothermia or dehydration. In addition, the building will also be protected against burst pipes or potential 
fire hazards.

 

 

Where should Temperature Extreme Sensors be fitted? 

 

The temperature extreme sensor should be fitted in the hallway or living room.  
It should be wall mounted at around 1.4 metres above floor level and away from any draughts or heat sources. 

 

Typical Tools Required 

 

A drill and screwdriver are not required if the self adhesive pad is used. 
Always make sure the correct drill bits and screwdrivers are used. 

 

Installation 

 Using Screw Fixings 

 

1.

 

Remove the top by pulling apart from the back section.  

 

2.

 

Drill the back section as required and fix to the wall using 
the screws & plugs provided. 

 

3.

 

Set the DIL switches & links, fit the battery and test as 
described on the following page before refitting the top section. 

 

 

Installation 

 Using Self Adhesive Pads 

 

1.     Remove the top by pulling apart from the back section. 

 

2.

 

Select the best location where the wall is clean, dry and even. 

 

3.

 

Stick the adhesive pad to the rear face of the back section and 
press firmly to the wall ensuring it is stuck securely. 

 

4.

 

Set the DIL switches and links, fit the battery and test as 
described on the following page before refitting the top. 
 
 
 
 
 
 
 

 
 
 
 
 

PULL APART 
TO REMOVE 

TOP 

SECTION 

FIX

 

BACK 

SECTION TO 

WALL 

Tynetec and Aidcall are business units of Legrand Electric Ltd 

Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth 

Northumberland, NE24 5TF. Tel: 

01670 352 371

 

Email: 

[email protected]

  Web

www.tynetec.co.uk

 

Отзывы: