background image

Doc No. FM0460 issue K Page 4  

Registering a Temperature Extreme Sensor onto an

 

Advent xt 

warden call system

 

 

1. 

Put the Advent xt system into radio device learn mode… 

 

  

  

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
2. Activate the temperature extreme sensor

 

 

 

 

 

 

 

 

 

 

               

 
 

 

 

 

 

 

 

 

  

 
 
 

 

 
 

 

 
3. Exit the Advent xt system radio 

device learn mode…

 

  

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
4. Press the TEST button and check a high temperature alarm call is reported on the warden call system followed by a low 
temperature alarm call about 20 seconds later. 

Remember to remove and refit the battery after the test call. 

 

 

 

Deleting a Temperature Extreme Sensor from an

 

Advent xt 

warden call system

 

 

Press the 

LINE

 

key and wait for the “

Ready

” prompt.

 

Enter 

5 0 0 1 

followed by the 

 key. 

Enter the flat number the temperature extreme sensor is being deleted from followed by the 

 key. 

Press TEST button on the temperature extreme sensor to be deleted.

 

W

ait for the “

Pendant Disabled 

 Enter Flat

” prompt.

 

Wait for about 20 seconds for the second 

Pendant Disabled 

 Enter Flat

” prompt.

 

Press the 

#

 

key and wait for the “

Ready

” prompt

, then press the 

LINE 

key to clear the connection.

 

 
 

 

 
 

Refer to the Advent xt operators manual (Doc No. FM0420) provided with the warden call system for more 
information on programming and testing radio devices.  

 
 

 
 

 

Using the Manager’s DECT telephone;

 

 

Press the 

LINE

 

key and wait for the “

Ready

” prompt.

 

 

Enter 

5 0 0 0 

followed by the 

 key. 

 

Enter the flat number the temperature extreme sensor is being installed 
in followed by the 

 key. 

 

You now have 1 minute to activate the temperature extreme sensor. 

 

Ready”

 

Using the Manager’s DECT telephone;

 

 

Press the 

#

 

key and wait for the “

Ready

” prompt.

 

 

Press the 

LINE 

key to clear the connection and the warden call system is 

now back in normal operating mode.

 

 

Press and hold the TEST button for about 3 seconds until the 

RED

 

light starts to flash. 

 

W

ait for the “

Enter Location Code

” prompt

 then press 

0

  

(no location) followed by the 

 key.  

 

Wa

it for the “

Pendant Enabled 

 Enter Flat

” prompt.

 

 

After about 20 seconds you will hear 

the “

Enter Location Code

” 

prompt again - press 

0

 (no location) followed by the 

 key.  

 

W

ait for the “

Pendant Enabled 

 Enter Flat

” prompt.

 

 

IMPORTANT: 

remove the battery to EXIT TEST MODE, leave for a 

few seconds then refit.

 

 

Ready”

 

 