background image

4

5

aidacare.com.au

INTRODUCTION

SYMBOLS USED IN THIS MANUAL

The Aidacare FL250 Bed is an electrically operated Floorline Bed offering 

functions and positional movements that assist caregivers and maximise 

patient comfort and safety. Ease of use, functionality, serviceability and cleaning 

practicality are key features of the bed. The bed has a robotically welded steel 

structure with a leading anti corrosion treatment layer underlying the durable 

powder coated finish. The plastic components are made from urethane,  

PP and POM nylon and ABS plastic.

CLINICAL APPLICATIONS AND AREA OF USE

This bed is appropriate for adult patient care and should only be used under the 

instruction of a carer or health professional where concerns exist around patient 

safe use.

KEY FEATURES

= 250kg

= 200kg

Maximum safe working load (SWL) of the bed is 250kg 

with a suggested maximum user weight of 200kg which 

conservatively takes into account common accessories 

used with care beds such as alternating pressure 

mattresses, assist bars and foam mattresses

•  ExitSafe single button 

ingress / exit height

•  BrakeFirst automatic safety brake 

activation at lowest height

•  SmartDescent automatically slows 

lowering speed from 300mm 

above floor level to lowest position. 

Designed to improve resident 

and carer safety whilst reducing 

potential for damage to equipment 

such as air mattress pumps 

becoming trapped under the bed

•  EasyMove Transport System 

– transport the FL250 bed 

with zero lifting for a truly safe 

manual handling process

•  Electrically adjusted height 

range from 110mm to 740mm

•  75mm twin castors with 

single activation locking 

mechanism for ease of use

•  Four section electrically operated 

mattress platform with independent 

adjustment of backrest angle 

(maximum 60°) and knee 

section angle (maximum 35°)

•  Bi-lateral mattress retainers 

with length adjustable mattress 

extension retainer at foot end

•  Integrated foot end 

extension. Extends the bed 

by 100mm or 200mm

•  Large range of feature 

enhancing accessories

•  Removable bed ends
•  Automatically adjusting 

wall protection system

•  Auto-regression integrated into 

backrest and leg section reduces 

sacral pressure, shear forces 

and abdominal compression 

during bed profiling

The symbols below are used throughout this owner’s manual and on the 

product to identify warnings and important information. It is very important  

for you to read them and understand them completely.

WARNING

Indicates a potentially hazardous condition/situation. 

Failure to follow designated procedures can cause either 

personal injury, component damage or malfunction. On 

the product, this icon is represented as a black symbol on 

a white triangle with a black border.

ALWAYS! These actions should be performed as specified. 

Failure to perform mandatory actions can cause personal 

injury and/or equipment damage.  

On the product, this icon is represented as a white infinity 

symbol on a black dot with a white border.

DO NOT! These actions are prohibited. These actions 

should not be performed at any time or in any 

circumstances. Performing a prohibited action can 

cause personal injury and/or equipment damage. On the 

product, this icon is represented as a white symbol with  

a black circle and black slash.

= 200kg

MAXIMUM PATIENT WEIGHT. This weight represents 

the total maximum weight of a patient on the bed. This 

weight (200kg) should not be exceeded at any time. 

= 250kg

SAFE WORKING LOAD (SWL). This weight represents  

the total maximum weight that the bed can carry, 

including patient, mattress, bedding, bed ends and 

accessories. This weight (250kg) should not be exceeded 

at any time. 

Please scan the QR code or visit our website aidacare.com.au 

and search ‘Aidacare FL250 (BEB046100 or BEB046150)’  

to access product marketing and technical documentation.

Содержание BEB046100

Страница 1: ...FL250 FLOORLINE BED USER MANUAL...

Страница 2: ...manual carefully before using your new bed TABLE OF CONTENTS Symbols Used In This Manual 4 Introduction 5 2 Safety Precautions 6 3 Overview 8 4 Specifications 9 5 Accessories 10 6 Electronic Functions...

Страница 3: ...angle maximum 35 Bi lateral mattress retainers with length adjustable mattress extension retainer at foot end Integrated foot end extension Extends the bed by 100mm or 200mm Large range of feature en...

Страница 4: ...tem must be reset when any changes are made to it Changes are defined as mains power is lost power outage turned off on mains cable is unplugged component cabling is disconnected from or connected to...

Страница 5: ...rade IP54 Standards Compliance Aidacare FL250 Beds are designed and manufactured where required in compliance with International Medical Device Safety standard IEC60601 1 IEC60601 2 52 All electronics...

Страница 6: ...day chairs Please contact Customer Service on 1300 133 120 for further information Code Description BEA030050 EasyMove Transport System Does not include bed shown BEB046200 BEB046220 Bed End Set Singl...

Страница 7: ...button is pressed Adjustment will stop when the button is released or the selection reaches the end of its range Auto Contour Conveniently positions patient into cardiac chair position for therapeutic...

Страница 8: ...Adjustable Mattress retainer 1 x Wall Buffer 1 x Handset 1 x Set of 2 Head Board Holders short 2 Foot Board Holders long 1 x Head Board Sold Separately 1 x Foot Board Sold Separately WARNING The FL250...

Страница 9: ...cord out as desired d Tighten cable gland to lock cable in place e Test bed through both its hi lo and backrest movement range and ensure the power cord does not get pinched or crushed by the frame An...

Страница 10: ...s pre stamped locator points insert the shaft into the bed frame until you feel or hear a click which is the bed frame lining up with the shaft locator point 18 Fasten each Holder at the locator point...

Страница 11: ...ch as forklift walkie stacker pallet jack hydraulic lift trolley etc lower the bed carton to 600 700mm from the ground 2 Carefully remove strapping and external dunnage materials remove the carton lid...

Страница 12: ...ght 4 Line up the Head Board Bracket Pegs with the Head Board Holder keyholes 5 Insert ensuring both sides are fully inserted push the Head Board down so the pegs drop into the bottom of the Holder ke...

Страница 13: ...1 x FOOT section LEFT second longest unique to this section and side 1 x FOOT section RIGHT second longest unique to this section and side Item 2a Hardware for Single Bed 18 x Attachment Bolts and Wa...

Страница 14: ...mount the SHP on left or right 5 Undo the left or right Head Board attachment bracket screws and remove the outside plate 6 Position the SHP attachment and receiver bracket over the Head Board holes...

Страница 15: ...cers NOTE If Side Panels are already fitted to the single bed they must be removed before the King Single Conversion Kit can be attached Recommended Tools Power Drill Right Angled Power Drill Adaptor...

Страница 16: ...nded Tools Power Drill Right Angled Power Drill Adaptor Fastening Folding Assist Bar to Bed 1 For best access to the bed frame side to attached the Folding Assist Bar use the FL250 EasyMove Transport...

Страница 17: ...owards the foot end of the bed as shown 4 Remove the 3 x bolts bushes and dome nuts from the mounting plate 5 If mounting to a King Single bed use the bushes supplied For a single bed only the bolts a...

Страница 18: ...ocate and unclip the cover exposing existing leads connected to ports and spare port 6 Position the battery back up lead so the groove is aligned with the spare port and insert fully into port 7 Reatt...

Страница 19: ...ally so the safety clip is to the right of the quick release axle 9 Lower the bed until the bed frame axle mount is level with the quick release axle on each EasyMove trolley 10 While pressing the qui...

Страница 20: ...e 26 If more than one hand is required there is likely to be an encumbrance on the pivot motion please check around the bed 27 When the bed frame is vertical re engage the pivot locks by pulling and t...

Страница 21: ...cable to beds with serial number prior to FL250 V2 2204 24505 4 Assemble USB port to the underside of the backrest using the mattress retainer legs as studs and secure in place with handwheels bed ser...

Страница 22: ...ort functions correctly Ensure cables have enough slack to accommodate all deck panel movements 13 Ensure cables are secured in place and protected from any moving parts of the bed Zip tie excess cabl...

Страница 23: ...s designed for use as a bed extension only and is not meant to support the body weight of a person sitting The extra length of the bed with extra load can also make the bed unstable potentially result...

Страница 24: ...leaning NOTE For easy access to all parts of the bed and for safe handling use the EasyMove Transport System NOTE The following procedure also applies to bed accessories but does not include mattresse...

Страница 25: ...the control box should always be reset to rule out any calibration issues Calibration issues can occur when power outages happen or when beds are unplugged from the wall during use To complete a reset...

Страница 26: ...cts where any original components have been changed or modified by non Aidacare approved and trained service maintenance staff or external providers Furthermore safety is not guaranteed where componen...

Страница 27: ...ABUM10 61 281122 AIDACARE PTY LTD Building 3A 1 Moorebank Avenue Moorebank NSW Australia 2170 1300 133 120 aspirecare com au MADE IN PRC...

Отзывы: