background image

Devices

15

NO ALARM - NO CHANCE!

Carbon Monoxide or (CO), is a particularly insidious gas. It is a killer.
The naked eye can't see it, it does not smell, it has no taste. The
need for a reliable mains powered alarm that will operate even in
the event of a mains failure is obvious.

The Ei professional range includes fully featured product usually
specified by Local Authorities & Landlords and less sophisticated
product where duty of care is not so much of an issue and where
the mains supply is more likely to be continuous and /or regular
battery maintenance is known to be reliably carried out.

The Ei261EN is the top of the range product. Current sensor
technology used by all manufacturers of CO alarms has a limited
life cycle; the sensors cannot be relied upon after a period of 5/6
years. The Ei261EN offers a 

replacement sensor feature

, thereby

increasing the life cycle of the product to ten years.

Ei261EN Mains Powered CO Alarm with
Rechargeable Lithium Cells and
Replaceable CO Sensor

10 year+ rechargeable lithium cell back-up designed to outlast 
the alarm 

Replacement sensor module, minimum five year life 

Easy to use test/hush button

Automatic self diagnostics

Distinctive alarm sound, easily distinguishable from a smoke alarm

Wall or ceiling mounting

Pre alarm warning

Interconnect feature - Can be interconnected with Ei smoke and
heat alarms. Contact us for details

Comprehensive Indicator lights: Mains on / Fault / Alarm on

Optional digital display - Ei261DEN

Quick CO gas test feature

RECHARGEABLE

LITHIUM CELLS

RECHARGEABLE

LITHIUM CELLS

EASY TO

REPLACE

SENSOR MODULE

EASY TO

REPLACE

SENSOR MODULE

INTERCONNECT 

FEATURE

INTERCONNECT 

FEATURE

BS EN 50291: 2001

ANCILLARY PRODUCTS

MCP401RC Manual Call Point

Supplied complete with surface 
mount box

Testing key supplied

Supplied with non-breakable
operating element

LPC approved, conforms to BS EN 54-11

Can be used with 140, 150, 160RC Models

SAB300 Remote Strobe Xenon Beacon

Mains powered

For internal or external use

Flash energy of 3 watts and flash
frequency of .9Hz

Clear or red lens options

For operation via an Ei158R or Ei128R relay

SABV4 High Intensity Strobe Xenon Beacon

Mains powered 

Ideal for use where standard strobes
may not be sufficiently visible

5 joule high intensity flash

Low current consumption

Red or opal lens option

For operation via an Ei158R or
Ei128R relay

YO3 Remote Sounder

Mains powered

Use in areas where a warning is
required - but a detector isn't

For internal or external use

Switchable sound outputs from 
97-100dB(A)

For operation via an Ei158R or 
Ei128R relay

MDH230 Magnetic Door Holder

Mains powered

Will automatically release a fire
door in the event of a fire

Test/Override button feature

Low current consumption 

For operation via an Ei158R or
Ei128R relay

Ei167 Remote Sounder

Interconnects with all mains
operated smoke and heat alarms

Ideal for use where an alarm but
no detection is required

AC mains indicator light

Carbon Monoxide

(CO) Alarms

NOW WITH

RC TECHNOLOGY OPTION 

Further details of all the products

featured on these pages are

available from our Customer Service

Helpline on 

0870 758 4000 

or visit

our website 

www.aico.co.uk 

and

download our product information

Содержание Ei169

Страница 1: ...CONTROL with REMOTE CONTROL functionality functionality New 160 Series now with REMOTE CONTROL functionality Product Guide for Smoke Heat Alarms Ahead on Quality Ahead on Performance Ahead on Feature...

Страница 2: ...llation All alarms should be interconnected The sound pressure level of the alarm signal measured at the doorway of each bedroom with the door open should be at least 85dB A Single storey Grade F LD3...

Страница 3: ...alarm technology should be accompanied by the very best support possible We offer unrivalled product information for end users of the product specifiers and installers On the ground we have an experi...

Страница 4: ...ay be a particular problem The BS 5839 Pt 6 2004 Standard recommends the use of optical alarms in circulation spaces of a dwelling such as hallways and landings Optical alarms are prone to false alarm...

Страница 5: ...e storey dwelling Optical or Ionisation smoke alarm as best suited for the particular circumstances Optical smoke alarm Smoke or heat alarm as best suited for the particular circumstances Heat alarm D...

Страница 6: ...es false alarms caused by insect contamination and fibres whilst allowing free access of smoke to the sensor chamber A dust cover is also provided for protection on site and prior to occupancy Ultra h...

Страница 7: ...s Date Code Identification BS Kitemarked CE Marked EMC Conformance BS Building Reg Grade D Compliance BS Building Reg Grade E Compliance Class II Double Insulated UV Stabilised Moulding Installer Inst...

Страница 8: ...disposal requirements A precision charging circuit ensures peak efficiency at all times 6 month back up even without mains power Cells supplied fully charged providing 6 months initial standby capaci...

Страница 9: ...be used effectively in larger and more complex applications including apartment blocks large houses HMOs and smaller commercial premises The alarms can be integrated with a number of additional device...

Страница 10: ...money on every installation Fixed cost interconnection Wire free interconnection and zoning capability Fully upgradeable system future proof Reliable interconnection Minimises risk of accidental mis...

Страница 11: ...ium cell back up to ensure the relay operates even during a mains failure Interfaces with other systems e g warden call and other signal devices Ei407 Wireless Manual Call Point Allows manual testing...

Страница 12: ...rs does not draw power until alarm is fitted to the mounting plate Hush button for false alarm control Interconnects with other Ei mains powered smoke and heat alarms Separate mains and warning LEDs T...

Страница 13: ...ke Alarm Ei176RF RadioLINK LV Optical Smoke Alarm Kit Ei178 Additional Strobe Ei174 Additional Vibration Pad Ei3105RF Additional RadioLINK LV Optical Smoke alarm 13 150 Series Local Authority Housing...

Страница 14: ...Heat Alarm Ei105R 12VDC Optical Smoke Alarm 140 and 160RC Series options Ei127 Surface Mounting Kit for use on uneven ceilings or where complicated wiring is used Ei128R As Ei127 with integral relay N...

Страница 15: ...RECHARGEABLE LITHIUM CELLS RECHARGEABLE LITHIUM CELLS EASY TO REPLACE SENSOR MODULE EASY TO REPLACE SENSOR MODULE INTERCONNECT FEATURE INTERCONNECT FEATURE BS EN 50291 2001 ANCILLARY PRODUCTS MCP401R...

Отзывы: