41
J4024-02 User Manual
Chapter 3. Sub-system Configuration Setup
3.6.3 Implementation on SES Pages
3.6.3.1 SES String In Page
Get PMBUS information with String In Page.
String In Format
Byte 0
I2C congestion status (0: no congestion, 1: congestion)
Byte 1~2
PSU Module1 STATUS_WORD
Byte 3~4
PSU Module2 STATUS_WORD
Byte 5~14
Reserved (0xFF)
3.6.3.2 SES Threshold Out / In
It includes only Temperature Sensor and Voltage Sensor elements.
Threshold control element format
BYTE/BIT
7
6
5
4
3
2
1
0
0
REQUESTED HIGH CRITICAL THRESHOLD
1
REQUESTED HIGH WARNING THRESHOLD
2
REQUESTED LOW WARNING THRESHOLD
3
REQUESTED LOW CRITICAL THRESHOLD
Threshold control element format
BYTE/BIT
7
6
5
4
3
2
1
0
0
HIGH CRITICAL THRESHOLD
1
HIGH WARNING THRESHOLD
2
LOW WARNING THRESHOLD
3
LOW CRITICAL THRESHOLD