16
Chapter 2. Hardware Setup
2�6�2 Internal Disk Drive
Remove the top cover from the chassis. Please refer to Section 2.3 Top Cover.
Lift and slightly rotate the 2.5-inch drive cage out of the chassis.
Press the ejector on the drive tray to release the handle.
Pull the drive tray outward completely.
Pull the tray out of the chassis.
This information is provided for professional technicians only.
2.5" SSD dimple placement 2.5" SSD screw placement
Insert the disk drive into the tray. Ensure that the dimples * 4 on the tray match the disk
drive. For additional assurance, fasten the screws * 4 on the tray to secure the disk drive.
NOTE
For this server product, 2.5-inch disk drive trays support SSDs only. Do not use insert
HDD into 2.5-inch drive tray.
Push the tray with the installed disk drive into the end of the drive slot in the chassis.
Close the tray handle.