Dry Cooler Type DXP100/120Air Cooled Condenser Type DCP100
12
Asarums Industri AB
Tel:
+46 454 334 00
Södra Industrivägen 2 – 4
Fax:
+46 454 320 295
SE – 374 50 AsarumSweden
2009-02-10
Страница 1: ...Cooler Type DXP100 120 Air Cooled Condenser Type DCP100 Asarums IndustriAB Tel 46 454 334 00 Södra Industrivägen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden Directions for use 61355 1 DCP100 DXP120 DXP100 ...
Страница 2: ...irective 2004 108 EC on the own responsibility of Company Asarums Industri AB S Industrivägen 2 4 SE 374 50 ASARUM Sweden Harmonized Standards EN ISO 12100 1 2003 EN 61000 6 1 EN ISO 12100 2 2003 EN 61000 6 2 EN ISO 13857 2008 EN 61000 6 3 EN 60204 1 2006 EN 61000 6 4 EN ISO 4871 The product is not allowed to put in operation until the machine or system which it is to be incorporated or which it i...
Страница 3: ...e DCP100 Asarums IndustriAB Tel 46 454 334 00 Södra Industrivägen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden INDEX P General description 4 System of designations 5 Receiving and fitting 6 Installation 7 Preventive maintenance 8 Lifting instruction 11 ...
Страница 4: ...e cooler is provided with axial fans and the casing is made of aluminium sheeting as standard Important Do not allow the product to be covered by foreign objects when in operation Unobstructed circulation of air is necessary to achieve the highest cooling efficiency The laminar surfaces of the battery must be free of deposits Item Designation Item Designation Item Designation 4 6 7 1 Cooler elemen...
Страница 5: ...ct the evacuation air because re circulation could otherwise occur This applies particularly to models that have low revs The cooler is to be mounted on a firm base and secured with foundation bolts The cooler frame is provided with pre drilled holes System of designations DXP100 120 7 A 256 X Number of passes A 865 rpm 3 400 V DXP100 B 670 rpm 3 400 V DXP100 C 450 rpm 3 400 V DXP100 D 355 rpm 3 4...
Страница 6: ...on before leaving the factory If faults or damage due to transportation are detected on the product the point of sale is to be contacted without delay Assembly 1 Move the product to the place of installation before removing the packing 2 The cooler is provided with eyebolts and shall only be lifted using these according to instructions on the cooler 3 Bolt the product direct onto a firm base or wi...
Страница 7: ...re they could damage the battery and thus cause leakage Tubing installation The product is to be filled with the amount and type of heat transfer medium stated by the installation engineer The connecting tubes are located on one end of the unit The air vent is at the highest point of the manifold tube 1 The incoming lead is connected to tube 2 The return lead is connected to tube 3 The drain 4 is ...
Страница 8: ...nal box 1 The fan unit weighs 45 to 55 kg Lifting tackle is recommended 3 Unscrew the screws 2 that hold the plate Lift out the fan unit by using strops under the arms 3 Standstill During long periods when the unit is not in operation the fans should be run at least four times a month They are to be run until the motor reaches normal working temperature i e for about 15 minutes Assemble the fan un...
Страница 9: ...e 5 Disconnect the electric cable from the motor terminal box 5 The motor weighs 25 to 120 kg Lifting tackle is recommended 6 Unscrew the screws 6 that hold the motor 7 to the motor shelf 8 Lift out the motor Preventive maintenance 3 1 2 4 5 6 7 8 Warning Make certain that the power supply is disconnected Assemble the fan motor DXP120 Assembling in reversed sequence N B After mounting the fan blad...
Страница 10: ...disconnected Cleaning the cooling battery 1 Remove the service cover 1 2 Cooling batteries that are lightly soiled can be cleaned by brushing and blowing with compressed air 3 Then wash the cooling battery with water and environment friendly detergent that does not corrode aluminium or copper Ammoniac may not be used 4 Rinse and allow to dry Caution Always wear protective gloves when cleaning or w...
Страница 11: ...P100 Asarums IndustriAB Tel 46 454 334 00 Södra Industrivägen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden Lifting instruction 1900 mm 3180 mm 4700 mm stl 4 6 3100 mm stl 1 3 4770 mm stl 10 12 3180 mm stl 7 9 3180 mm 1900 mm 6360 mm stl 13 15 1900 mm 4770 mm ...
Страница 12: ...Dry Cooler Type DXP100 120 Air Cooled Condenser Type DCP100 12 Asarums IndustriAB Tel 46 454 334 00 Södra Industrivägen 2 4 Fax 46 454 320 295 SE 374 50 Asarum Sweden 2009 02 10 ...