MENU
Function C
11
0 = OFF
1 = A
2 = B
3 = A-B
4 =
±
A
5 = A/B
6 = B/A
7 = A+B
2
8 = A-B x 100
A
9 = B-A x 100
A
The mathematical functions which can be computed in each mode of operation are listed
in Section
2.1
.
Note:
A + B can be computed by using a negative scaling factor for the B channel.
Note:
With bi-directional operation, when a bidirectional sensor is connected to the instru-
ment, Speed A can be computed from one frequency input (TTL input A) and direction can
be computed from TTL input B. High (+5V) indicates a positive direction. Only single speed
functions (Speed A) are useful when connected in this operation mode. In addition, channel
B can be connected to any type of limit switches when using Function 4 (
±
A).
Note:
With dual channel operation, when ratio and elongation functions are selected
(Functions 5, 6 and 9), the ratio of zero over zero, by definition is unity (1).
4.3 DEFINING THE BEHAVIOR OF THE OUTPUTS
4.3.1 Display
You can program the Display to show the computed function of channel A and/or channel
B, and you can configure the instrument to compute in one unit of measurement and to
display another by altering constant C
5
. (See page 3.)
Autoranging
Autoranging refers to the movement of the decimal among the 4 1/2 digits on the Display.
You can limit the movement of the decimal point, and thereby determine the smallest value
the Display will show.
4.3.2 Analog Output
Zero Scale
You can determine at which value of the analog function the analog output delivers 0 or 4
milllamps to the load.
7
Содержание TACHTROL 3
Страница 1: ...TACHTROL 3 ...
Страница 23: ...2 NEMA 4X 3 X STYLE 4 LESS ENCLOSURE STYLE 19 ...