background image

10

• Typical Applications....

SWX-200P

High performance music system for large enclosed area

SSA-350

'Y' Cord

SSA-350

Connect the left and right outputs of the CD player 

Place the subwoofers preferably in any corner on 

to the Aux-2 input (200mV) of Ahuja PA amplifier 

the floor, with the reflecting port preferably not 

SSA-350 using a 'Y' cord (with two RCA plugs at 

facing the corners. Also, it is recommended to 

one end and a ¼” phone plug on the other end).

place the two subwoofers together. Keeping them 
far apart may result in the loss of bass effect at 

A paging microphone can also be connected to 

some locations.

any one of the mic inputs of SSA-350 to make 
announcements.

Set the crossover frequency of each subwoofer to 
80Hz and adjust the volume control to deliver 

10 nos. of Ahuja high fidelity 2-way speakers 

optimum performance.

PS-500T (at 32 watts tap) can be connected to the 
100V output terminal of amplifier SSA-350.

Connect the Line output of the amplifier SSA-350 
to the 1V inputs of the two powered subwoofers 
SWX-200P, using a 'Y' cord (with ¼" phone plug at 
one end and two ¼" phone plugs at the other end).

1V Input

1V Input

100V Line Output

Line Output

Aux-2 Input

PS-500T

SWX-200P

(B)

SWX-200P

(A)

Microphone

Mic

Input

CD Player

'Y' Cord

Содержание SWX-200P

Страница 1: ...sing the AHUJA Powered Subwoofer Please read this manual thoroughly before making connections and turning on the power Following the instructions in this manual will enable you to obtain optimum performance from your new AHUJA Powered Subwoofer Please retain this manual for future reference ...

Страница 2: ... harmful chemicals Do not place heavy objects on the power cord Operation on Generator When operating the powered speaker on a generator make sure it is switched OFF till the generator voltages has stabilized and then only switch the powered speaker ON Protection Against Shocks Do not plug in or remove the power supply plug with wet hands so as to avoid electric shock Replacing AC Mains Fuse After...

Страница 3: ... No Features General Description of Product 4 Rear Panel Controls Description 5 Interconnections 6 Placement Operation of Product 7 Typical Applications 8 Block Diagram Specifications 12 Table of Contents 3 SWX 200P ...

Страница 4: ... in an elegant PVC coated wooden cabinet Available in OAK and Black finish Vented Down firing speaker System using an 8 high output LF driver Built in 100W low distortion direct coupled amplifier to produce powerful bass SWX 200P has two unbalanced independent inputs One accepts signals of 200mV and the other accepts 1V signals Built in fourth order electronic Low pass filter with selection of 80 ...

Страница 5: ...rips The circuit protector prevents the powered audio amplifier Sensitivity is 200mV subwoofer from getting damaged on account of short circuits DC offset and Overdrive conditions 11 Line Input Jack socket Rectify the cause and press the RESET button For accepting an unbalanced signal from an for resetting normal operation of the subwoofer audio mixing console or the line out of an audio amplifier...

Страница 6: ...or earthed mains outlet accepting an unbalanced signal from a Cassette player recorder or the preamp output of an audio All connections must only be carried out or changed amplifier with the amplifier switched OFF The 1V sensitivity input jack can be used for The SWX 200P has two unbalanced independent accepting an unbalanced line level signal from a inputs One accepts signals of 200mV and the oth...

Страница 7: ...should be adjusted so that volume of bass information seems pleasing In case the CLIP LED flickers it is recommended to turn down the output level from the subwoofer This will prevent the excess power from damaging the SWX 200P woofer Crossover Adjustments The crossover frequency selector switch located on the top chassis of the powered subwoofer SWX 200P determines the highest frequency at which ...

Страница 8: ...one plug at the other selected through a CD Aux switch in 4040 SM end A paging microphone can also be connected to the Place the subwoofer preferably in any corner on mic input of the 4040 SM to make announcements the floor with the reflecting port preferably not facing the corners Connect 2 nos of high fidelity 2 way speakers PS 300T at 8 ohm tap in parallel resulting Set the Crossover frequency ...

Страница 9: ...he Mono Stereo switch of the amplifier length with phone plugs on both ends TZA 2000 should be kept in Mono position Place the subwoofer B preferably in any corner on 6 nos of Ahuja ceiling speakers CS 8151T at 15 the floor with the reflecting port preferably not watts tap can be connected to the 100V output facing the corners terminal of Zone A of the amplifier TZA 2000 Set the crossover frequenc...

Страница 10: ...in the loss of bass effect at A paging microphone can also be connected to some locations any one of the mic inputs of SSA 350 to make announcements Set the crossover frequency of each subwoofer to 80Hz and adjust the volume control to deliver 10 nos of Ahuja high fidelity 2 way speakers optimum performance PS 500T at 32 watts tap can be connected to the 100V output terminal of amplifier SSA 350 C...

Страница 11: ...referably not output connections for each of the five satellite facing the corners speakers The output level of the satellite Set the crossover frequency of the subwoofer to speakers can be adjusted from the AV receiver 80Hz and adjust the volume control to deliver When using the powered subwoofer SWX 200P in optimum performance conjunction with AV amplifiers and receivers with surround capability...

Страница 12: ...03 mm 8 SPL 1W 1m 90dB Frequency Response 3dB 27Hz Crossover Frequency Subsonic Filter 4th Order 27Hz Crossover Frequency Switchable 80Hz 120Hz Low Pass Filter 24dB octave Output Regulation 0 5dB Input Channels 1 Input 200 mV 10k 1 Input 1V 10k S N Ratio 75dB Protection AC Fuse 1 3A DC 2 4A Circuit Protectors Power Supply AC 220 240V 50 60Hz Finish Oak or Black PVC Laminate Dimensions W355 H435 D4...

Отзывы: