manualshive.com logo in svg
background image

1.4 | Display and acknowledge alarm

AHT Cooling Systems GmbH | en

6 / 8

402376_1_0619

Error

code

Meaning

Meaning (EN)

On Failsafe

On Failsafe

HW failure or Mod-

bus flashing

HW failure or Modbus

flashing

Air in sensor

Air in sensor

Air out sensor

Air out sensor

Fin sensor

Fin sensor

Discharge pressure

sensor

Discharge pressure

sensor

Compressor safety

(High pressure/Low

pressure)

Compressor safety

(High pressure/Low

pressure)

Cabinet temperature

sensor (HACCP)

Cabinet temperature

sensor (HACCP)

Low supply voltage

Low supply voltage

Battery defective

Battery defective

Class B software

Class B software

EEPROM (controller

defective)

EEPROM (controller

defective)

High cabinet temper-

ature

High cabinet temper-

ature

Low cabinet temper-

ature

Low cabinet temperat-

ure

Low control temper-

ature

Low control temperat-

ure

High control temper-

ature

High control temperat-

ure

Defrost terminated by

time

Defrost terminated by

time

SD card defective

SD card defective

Bus alarm

Bus alarm

Configuration

Configuration

Acknowledge alarm

Acknowledge
acoustic alarm

Press 

.

The error code cannot be acknowledged. It is dis-
played until the error is rectified.

Содержание VENTO GREEN

Страница 1: ...triebsanleitung Gewerbliches Kühl Gefriergerät Supplement to Operating instructions Commercial refrigeration appliance Snr 402376 Version 1 Status 0619 Copyright AHT Cooling Systems GmbH Alle Rechte vorbehalten VENTO ...

Страница 2: ...Beiblatt zu Originalbetriebsanleitung 347411 de 3 Supplement to Translation of the original instructions 347411 en 5 AHT Cooling Systems GmbH 2 8 402376_1_0619 ...

Страница 3: ...Nachtrollo offen Gerätebeleuchtung an Alarm 1 1 Kühlfunktion ein und ausschalten Standby Kühlfunktion nur für Reinigungszwecke ausschalten Kühlfunktion aus schalten 5 s drücken wird am Display angezeigt oder drücken bis am Display erscheint drücken wird am Display angezeigt Kühlfunktion ein schalten 5 s drücken oder die Innenraum Temperatur und die Symbole werden nach einigen Sekunden am Display a...

Страница 4: ...ty High pressure Low pressure Warenraumsensor HACCP Cabinet tempera ture sensor HAC CP zu niedrige Versor gungsspannung Low supply voltage Batterie defekt Battery defective Software Klasse B Class B software EEPROM Steuerungs platine defekt EEPROM controller defective zu hohe Warenraum temperatur High cabinet tempe rature zu niedrige Waren raumtemperatur Low cabinet tempe rature zu niedrige Regelt...

Страница 5: ...ndby Switch off cooling function for cleaning purposes only Switch off cooling function Press 5 s appears on the display Press or until appears on the display Press appears on the display Switch on cooling function Press for 5 s or the interior temperature and the symbols appear on the display after a few seconds 1 2 Semi automatic defrost Start semi auto matic defrost Press for 5 s appears on the...

Страница 6: ...perature sensor HACCP Low supply voltage Low supply voltage Battery defective Battery defective Class B software Class B software EEPROM controller defective EEPROM controller defective High cabinet temper ature High cabinet temper ature Low cabinet temper ature Low cabinet temperat ure Low control temper ature Low control temperat ure High control temper ature High control temperat ure Defrost te...

Страница 7: ......

Страница 8: ...edreiras Navegantes SC 88375 000 Brasil Phone 55 0 11 4702 30 99 Fax 55 0 11 4702 71 68 Email info br aht at AHT Cooling Systems Changshu Co Ltd 215500 Changshu 88 Yangguang Avenue Jiangsu Province P R China Phone 86 512 5236 7100 Fax 86 512 5236 2393 Email office cn aht at AHT Cooling Systems USA Inc 7058 Weber Blvd Ladson SC 29456 USA Phone 1 0 843 767 6855 Fax 1 0 843 767 6858 Email info us aht...

Отзывы: