347345_1116 40
AHT Cooling Systems GmbH
low temperature. Frostbite on the skin.
▶ Wear protective gloves and protective cloth-
ing when loading.
closing the glass doors. Hands (body parts)
can get pinched on the hinge side or the
handle side.
▶
Do not grip the open gap when closing the
doors, especially not on the hinge side.
▶ Look out for others when closing the doors.
NOTICE
Property damage
due to improper use.
▶ Only load the appliance with products when the
temperature stipulated for the respective product
has been reached.
▶ Open the glass door to an opening angle of 90°.
▶ Put products away with care.
▶ Always open only one door for loading. Never open
several doors at the same time.
▶ Never leave the glass door open for longer than
10 minutes for loading. It is recommended to load
the appliance in the evening, in order to prevent a
restricted view of products as a result of frost forma-
tion.
▶ Always completely close the glass doors after loading.
▶
Do not block the air intake grille with products.
▶ Loading is only allowed up to the border of the air
intake grille (see
➙
Fig. 8).
▶ Do not load beyond the edge of the shelving.
▶ Load the display racks to a maximum height of 50
mm below the next display rack.
▶ The stacking limit is indicated by stacking marks in
the appliance (see
➙
Fig. 9).
▶ Completely close the glass doors after loading.
Fig. 8: Air intake grille (example photo)
Fig. 9 stacking mark (example image)
NOTICE
Material damage
due to loss of stability of the appli-
ance. Deformation of the display racks.
▶ The display racks and back panel of the appliance
must be installed properly.
▶ Appliance back panel and lateral display rack must
be in place.
▶ Mounting brackets must be correctly inserted into
the rear panel of the appliance.
▶ Display racks must be inserted at the same level.
▶ Observe the maximum loads of every type of stor-
age rack (see
➙
Chapter 2.2).
Fans in this area reduce their speed when the glass door
is opened. The resulting noise change in the appliance is
normal and does not indicate a fault.
Remove any water that accumulates on surfaces (seals
and frames) before closing.
NOTICE
Material damage
due to mechanical removal of frost /
ice on glass doors. Destruction of the coating results in
a restricted view of the products.
▶ Do not remove frost/ice from glass surfaces with
hard mechanical tools (e.g. ice scrapers).
▶ Do not hold the door open with the body when load-
ing it.
9.2
Commissioning and re-commissioning
WArNiNG
Working on the electrical system. contact
with any parts carrying live voltage can
cause an electric shock.
▶ Only specialist personnel are permitted to
carry out work on the electrical system.
▶ Observe the electrical safety regulations
before beginning any work.
1. Disconnect the appliance.
2. Safeguard the appliance against uninten-
tional restart.
reasons for decommissioning by specialist personnel
∙
Maintenance, service, repair (see
➙
Chapter 10.2)
∙
Main cleaning (see
➙
Chapter 10.1.3)
∙
Defrosting
∙
Disposal (see
➙
Chapter 11)
By operating personnel
∙
A shutdown in normal operation is not intended.
9.2.1 Decommissioning
For
specialist personnel
, the procedure is described in
detail in the corresponding service manual.
Only trained operating personnel and specialist personnel
are permitted to carry out decommissioning.