AHN myLab HC-01

Hematocrit Centrifuge 12000 rpm

Instruction Manual

Содержание myLab HC-01

Страница 1: ...AHN myLab HC 01 Hematocrit Centrifuge 12000 rpm Instruction Manual ...

Страница 2: ......

Страница 3: ...IES 1 5 TECHNICAL SPECIFICATIONS 1 6 SAFETY PRECAUTIONS 2 7 INSTALLATION 3 8 STANDARD PARTS LISTING 4 9 USER INTERFACE AND DISPLAY 5 10 ROTOR INSTALLATION 5 11 OPERATING THE CENTRIFUGE 7 12 MAINTENANCE AND CLEANING 8 13 TROUBLESHOOTING 9 14 WARRANTY STATEMENT 10 15 PRODUCT DISPOSAL 11 ...

Страница 4: ...eration and care of the unit only and not its repair For repair pleasecontactthesupplier 3 PRODUCT FEATURES Ÿ BrushlessDCmotorformaintenancefreelonglife Ÿ PreciseRPMsettingfrom500to12000RPMwithleastcountof100RPM Ÿ Lidlocksafety Lidreleasesautomaticallyafterruncompletion Ÿ Timersettingupto12minutes Ÿ RPM RCFtogglesalternativelyonthedisplayduringoperation Ÿ LargeLCDdisplayforeasysettingandreadingmul...

Страница 5: ...etechnician Ÿ Usingincorrectrotors wrongsparepartswillvoidthewarranty Ÿ Centrifuge may be used for the specified applications only It must not be operated in a hazardous or flammable environment and must not be used to centrifuge explosiveorhighlyreactivesubstances Ÿ If liquids are spilled on the rotor or rotor chamber the centrifuge must be cleaned carefullyandproperlybeforebeingusedagain Ÿ Prior...

Страница 6: ...magethecentrifuge Ÿ The power adaptor given with centrifuge unit is designed to use for that particular centrifuge Do not use any other power adaptor using any other power adaptor maydamagethecentrifugeandwillvoidthewarranty 7 INSTALLATION Open the box then remove the packaging and gently take the centrifuge out of the box Before using this centrifuge open the centrifuge remove all packaging from ...

Страница 7: ...h the s cker posi on as shown in thefigurebelow gentlypushitin 7 INSTALLATION 4 Ifmatchedcorrectlytheplugwillgoineasilywithoutmuchforce donottry toforce thepluginifitisnotmatchedproperly Oncetheplugisinsertedintoposi on turn theloosenedupperringclockwiseun litis ghttosecurethefitment 8 STANDARD PARTS LISTING 2 1 3 Match the rib and slot Match the sticker Centrifuge Lid Rotor Lid Nut Display Lid Lock...

Страница 8: ...pens automatically after rotor comes to a stop 4 P1 6 To enter preset mode press P1 long press to exit the mode P2 7 To enter preset mode press P2 long press to exit the mode 5 9 USER INTERFACE DISPLAY 10 ROTOR INSTALLATION ROTOR REMOVAL AND REPLACEMENT PROCESS The rotor comes pre installed with the centrifuge If you want to remove or replace therotor followtheinstructionsbelow REMOVING THE ROTOR ...

Страница 9: ... or loosen the rotor lid before removingtherotor 1 Always balance the rotor before centrifugation Above are examples of properly balancedrotors 2 Thesamplesinthetubesshouldbeofequalvolume 3 If the tubes are not loaded correctly vibration or imbalance can occur which can causeseriousdamagetothecentrifuge 4 If the tubes are not loaded symmetrically then the imbalance detector will cut off therunning...

Страница 10: ...PM RCF button use setting and to change speed Changing the speed between the ongoing centrifugation will run the centrifuge at updated speed for the rest of time as indicates by the timer The speed can be selected in RCF value too Long Press RPM RCF button to change the RCF setting Press the button to increase or decrease the value Blinking of RCF value will stop and the RCF value will be stored a...

Страница 11: ...centrifuge is running LED light will be ON Pressing the STOP OPEN button will stop the operation Once operation is over centrifuge lid will open automatically If lidisnotopenpress STOP OPEN button toopenthecentrifugelid NOTE In case of power failure once the rotor has stopped pull out the emergency lid releaseasshowninthefigure Thiswillopenthe centrifugelid 8 12 MAINTENANCE CLEANING Before cleanin...

Страница 12: ...Lid Open No main power connection Power check proper plug in of main cable at both ends Power failure Check the mains fuse of the lab Connect adaptor properly Improper connection Lid not closed correctly Close lid correctly Contact service representative Error with lid closing and opening mechanism Rotor not loaded symmetrically Load rotor symmetrically restart centrifuge Err 55 Rotor is still spi...

Страница 13: ...identalorconsequentialdamages commerciallossor anyotherdamagesfromtheuseofthisproduct The warranty is invalidated by any non factory modification which will immediately terminate all liabilities on us for the products or damages caused by its use The customer shall be responsible for the product or use of products as well as any supervision required for safety If requested the products must be ret...

Страница 14: ...es supplied after 13 06 05 in the business to business sphere to which this product is assigned may no longer be disposed off in municipal or domestic waste They are marked with thefollowingsymboltoindicatethis As disposal regulations within the EU may vary from country to country pleasecontactyoursupplierifnecessary applicabletotheoriginalpurchaser Products received without proper authorization w...