Quick Start Setup Instructions for Müller ISO 

RCM - Single Product

 

 

PLEASE NOTE: Your setup may vary. Not all screens are shown. See 

Müller Operator’s Manual for safety information and additional 

setup/operating information.

 

Master Switch 

•Master Switch to turn 

on and off system when 

physical Master Switch is 

not enabled

 

Configuration 

Advance 

Settings

 

Speed Settings

 

Distance

 

Measurements

 

Section Configuration

 

Diagnostics

 

Tank 

Refilling 

Tank

 

Emptying 

Tank

 

Rate Adjustment 

Rate Target 

Selection

 

Auto/Manual

 

Rate

 

Increase/

 

Decrease

 

Road Mode 

Road Mode function is 

used for safe transport 

on public roads

 

 

Next Page 

Displays 

further function

 

icons

 

 

Counters 

This opens a screen 

with counters.

 

 

Sections 

•Opening and 

closing

 

section 

valves from left 

to right or from 

right to left

 

 

 

 
 

 

 
 
 

 

Müller

-

Elektronik

’ 

technology

 

is

 a very 

flexible

 

control

 

plat

form 

with many

 

capabilities.

 

This

 

quick

 

start

 

setup

 

guide

 

will

 

show

 

you 

th

necessary

 

steps

 

to

 

setup

 

your

 

display

 

to

 

control

 

AgXcel’ s

 

Fertilizer

 

Pump

 

Systems.

 Follow 

the

 general 

directions

 

in

 

your

 

Müller's

 

User

 

Manual

 

(especially

 

under

 

Configuration

 and 

Liquid

 

Rate

 

Control

). 

This

 

manual

 

will

 

show

 

you

 

the

 

specific

 

numbers

 and 

settings

 

to

 

use with

 

your

 AgXcel 

Fertilizer

 

Pump

 

System

.

 

 

MENU STRUCTURE FOR LIQUID RATE CONTROLLER 

 

On the Next Page…

 

System Information

 

Virtual Terminal (VT)

 

When your Müller

 

ISO Liquid Rate Controller is correctly connected, it

 

will be discoverable in your monitor's Virtual Terminal 

section. Select the Virtual Terminal icon, which

 can 

be in

 

different areas of the controller.

 

From the “

Home

” screen, press the “

VT

” 

or “

ISO

” 

icon on the

 

bottom of the screen, which will take you to the

 

Virtual 

Terminal 

screen.

 

Once on 

the

 

Virtual Terminal 

screen,

 

your Müller

 

ISO

 

module will be

 

detected. Once

 

detected, it will

 

load your current

 

configurations.

 

If this is your first time setting up, it will display a message letting you know that system has not been

 

configured.

 

 

AGXCEL, 

LLC

Содержание Muller ISO

Страница 1: ... platform with many capabilities This quick start setup guide will show you the necessary steps to setup your display to control AgXcel s Fertilizer Pump Systems Follow the general directions in your Müller s User Manual especially under Configuration and Liquid Rate Control This manual will show you the specific numbers and settings to use with your AgXcel Fertilizer Pump System MENU STRUCTURE FO...

Страница 2: ...ts the ECU for demo purposes SYSTEM CONFIGURATION System configuration is where you will set the Müller ISO to be compatible with the AgXcel fertilizer system AgXcel has found the best settings to work with their fertilizer pump systems Please carefully follow each step to set up your controller Setting up for Single Product Locate your Müller ISO system password located in your user manual This p...

Страница 3: ...that NO controlling corrections will be made to the control valve A low number may result in oscillation around the target rate High number may result in not achieving the target rate Minimum Maximum Time Min ms is the value the output will start from no matter how much correction is needed Max ms is the max value the output will reach once saturation of the output has been reached Press the 3 dot...

Страница 4: ...s in Tank Size User Preference Meter Cal Please see Chart below Pressure Sensor If a pressure sensor is installed please select Analog option If an electric pressure sensor is not installed please select Not Installed option When using AgXcel s optional Pressure Transducer Kit PN 53491 Next Page Icon Once completed Press the Back Icon to return to the Configuration screen Configuration 1 4 Configu...

Страница 5: ... This allows for quicker return to the Target Rate when you start applying again Only use this if you have a return line back to the tank This can cause high pressure if no return is plumbed Warning If Lock at Last is enabled and there is no return line plumbed flow will not be able to stop The Master Switch will not have the ability to turn off product flow Jump Start Unchecked Check the Jump Sta...

Страница 6: ...ber of Sections From the Run Screen press the Configuration icon Then press the Sections Configuration icon The Sections screen will appear shown on right If the section number is unchecked the system will disable the specific section and it can t turn on from the Run Screen This feature allows the operator to disable the sections that aren t going to be used Enter the number of sections in the To...

Страница 7: ...alarm to alert the operator when the Actual Rate is greater than 25 of the Target Rate If the system has a dump valve this feature can protect the pump and keep it from burning up Entering the Fill Amount in the Tank You must input the amount of product in your tank prior to starting to operate for the system to correctly display tank content Current Volume This will display the current gallons th...

Страница 8: ...guration icon Press the Pressure Calibration icon Pressure Sensor Select the name of the product for the Pressure Sensor Offset 0 00 v The offset setting allows adjustment to the voltage range The range can be increased or decreased Slope 0 00 psi V The Slope value shows psi V for the pressure sensor 1 volt 20psi Current Pressure This value is the current pressure reading from the Pressure Sensor ...

Страница 9: ...not be used when the product type is anhydrous The simple catch test is completed in calibration screens and done statically The user starts application and catches flow from a single nozzle for 1 minute or a measured time interval The system converts the catch amount to a gal min value and enters it in the calibration screens Because the number of pulses per gallon can change during the lifespan ...

Страница 10: ...nt to apply during the catch test with the section control icons Press the Master ON OFF icon to start application Apply product for 1 minute Press the Master ON OFF icon to stop application Enter the applied amount in gallons in the Actual Amount line Once this amount is entered the Meter Cal value will be updated The user can accept the updated value with by pressing the check mark or press X to...

Страница 11: ...tronic solenoid can control the hydraulic flow I am trying to achieve 12 GPA but my system will only go up to 8 GPA on my GX5 Hydraulic system or I am trying to achieve 8GPA and can only achieve 5 GPA on my GX2 electric system AgXcel GX2 Electric System What is your system pressure If system pressure is too high 50PSI or above this will prevent you from achieving your highest rate possible High sy...

Страница 12: ... and make sure that all are set correctly My rate is fluctuating and is almost locking in but is jumping around Make sure that your Rate Smoothing is checked and set to 10 You can typically find this setting under your System Controller settings Rate Smoothing allows the system to lock into the rate if the rate is within 10 of the required rate Many times liquid temperature can affect the performa...

Страница 13: ... Tube to a larger hole size If your pressure is too LOW then change the size of your orifice or Micro Tube to a smaller hole TIP Many times the system may have difficulty priming or if a flow meter has not detected flow and you want the system to continue running so as to prime Go to Diagnostics Tests Calibrate PWM Limits 1 Time for Auto Mode Testing 2 Once again enter a Test Speed 3 Press the AUT...

Страница 14: ...NEL 1 PWM AgXcel Müller Integration Harness Dual Liquid Product Agxcel 56410 320 587 Wire Size 18 AWG Length 3ft Version 1 0 Edited 7 22 2021 38 39 40 41 42 SECTION 01 SECTION 02 12V HIGH CURRENT 12V ELECTRONIC ELECTRONIC GROUND HIGH V GROUND PRODUCT 2 SECTIONS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 VALVE GROUND SECTION 01 SECTION 02 SECTION 03 SECTION 04 SECTION 05 SECTION 06 SECTION 07 ...

Страница 15: ...RE SIGNAL FLOW GROUND MASTER ON OFF POWER FLOW SIGNAL Agxcel 53697 309 506 Wire Size 18G Length 10ft AgXcel Channel Integration Harness PWM Flowmeter Pressure Version 1 1 Revised 08 15 22 PRESSURE A B C PRESSURE SIGNAL 1 POWER FLOW GROUND 12V FLOW A B C FLOW SIGNAL POWER FLOW GROUND MASTER ON OFF A B C SIGNAL POWER GROUND PWM A B PWM PWM A G X C E L L L C ...

Страница 16: ...el 53594 309 504 Wire Size 18 G Length 11 ft Revised 1 2 Created 07 02 18 Updated 08 16 22 SECTION 8 SECTION 11 SECTION 10 SECTION 9 SECTION 12 PRESSURE VALVE POWER VALVE POWER SECTION 6 SIGNAL 12V A B C PRESSURE GROUND 12V SIGNAL A B C SECTION 5 12V A B C SECTION 4 12V A B C SECTION 3 SECTION 2 12V A B C SECTION 1 12V A B C 12V A B C SIGNAL SIGNAL SIGNAL SIGNAL SIGNAL GROUND GROUND GROUND GROUND ...

Страница 17: ...ECTION 11 SECTION 10 SECTION 9 SECTION 12 PRESSURE VALVE POWER VALVE POWER PRESSURE GROUND 12V SIGNAL A B C SECTION 7 12V A B C SECTION 6 12V A B C SECTION 5 SECTION 4 12V A B C SECTION 3 12V A B C 12V A B C SIGNAL SIGNAL SIGNAL SIGNAL SIGNAL GROUND GROUND GROUND GROUND GROUND SECTION 8 12V A B C SIGNAL GROUND SECTION 9 12V A B C SIGNAL GROUND SECTION 10 12V A B C SIGNAL GROUND SECTION 11 12V A B ...

Отзывы: