0017/0056
00490S06.004
00490S06.003
00490S06.006
00490S06.005
00490S06.008
00490S06.007
00490S06.010
00490S06.009
>
<
1
2
3
4
5
6
7
9
8
22
.08.06
06:20
0
<-
->
Edit
.
Version April 2008
EN
23
agru SP 315-S User’s Manual
line mode. Check for potentially damaged connections from the machine
to the printer or the PC.
After successful printing, the machine displays a message telling the
welder that printing was o.k.
5.2
Showing Reports in Memory, Reprinting Tags
Using the appropriate option of the configu-
ration menu (see section 4.3), it is possible
to display on the screen the welding reports
saved to memory. A screen like the one in
Display 20 appears. It is similar to the weld-
ing and traceability data overview shown at
the end of each successful welding. opera-
tion. The “Error” field reads “Ok” if no error
occurred, and contains the acronym “PH”
(for „Pre-Heat“) if the welding operation was
performed with the pre-heating feature.
Near the left edge of the Report Info screen,
you will find a list of all welding reports cur-
rently in memory. Above this list, the number
of the selected report is given (before the
slash), along with the total number of reports
in memory (after the slash). To move the selector bar through the list,
touch the scrollbar arrows to the right of the list. The longer you touch
them, the faster the bar scrolls through the list.
To display the welding and traceability data of the selected report, touch
the “Select” button after having selected it in the list. This will populate
the fields in the right-hand part of the screen with the values saved to the
selected welding report. To reprint an extra tag of this welding operation
for sticking it onto the pipe, touch the “Tag” button.
5.3
Deleting Reports from Memory
To delete the reports stored in memory, use the appropriate option in the
configuration menu (see sub-section 4.3). Upon touching this button, a
safety warning asking if you really want to delete them appears on the
screen and has to be confirmed to effectively delete the reports currently
in memory.
6 System
Data
6.1
Setting the Date and the Time of Day
W h e n t h e “ D a t e / T i m e ” s u b - m e n u wa s
selected in the configuration menu (see
sub-section 4.3), the screen shows what is
reproduced in Display 21.
The time of day and the date can be set
using the keypad shown on the touchscreen
panel.
6.2
Enabling Automatic Heating
When the “Automatic Heating” sub-menu
was selected in the configuration menu (see sub-section 4.3), the screen
shows what is reproduced in Display 22.
Report Infos
Select
agru SP 315-S 26.04.08 15:33
+16°C
Ok
Display 20
Material
Heat nominal Date
Diameter
Heat actual
Time
Wallthickness Ambient Temp Welder
SDR
Distance
Error
Tag
Set Date/Time
Cancel
agru SP 315-S 26.04.08 15:33
+16°C
Ok
Display 21
Time
Date
Содержание SP 315-S