Agrowtek GrowControl SXC Скачать руководство пользователя страница 5

5

© Agrowtek Inc. | www.agrowtek.com

Techno

logy to Help Y

ou Gro

w

AGROWtEK

U.S.A.

MADE IN

© 2016 Agrowtek Inc.

www.agrowtek.com

GrowControl

SXC

TM

TEMP

RH

LIGHT

CO2

if equipped

KEEP 
FAN
FILTER
CLEAN

Connection to MODBUS RTU

Serial Speed & Format

RS-485

Use the LX2 ModLINK to connect MODBUS devices to the GrowNET™ port.

HX8 8-Port Hubs

HX8 GrowNET ™ Hubs allow multiple GrowNET™ sensors, relays and 

dosing pumps to be connected to a single LX1 or LX2 interface. Indi-

vidually buffered, full-duplex ports for signal integrity. Hubs can be 

daisy chained to form a network of up to 247 devices.

Hubs provide up to 1A of power for operating sensors and some re-

lays directly over the GrowNET cable. A DC jack on the hub provides 

24Vdc power to the ports from the included 120V wall power supply.

Technology to Help You Grow

AGROWtEK

U.S.A.

MADE IN

© Agrowtek Inc. | www.agrowtek.com

TM

GrowNET  8-Port Hub

GrowControl

TM

8    7    6    5   

POWER

12-24Vdc

GrowNET
Upstream
Port

TM

HX8

The default serial data format for the LX2 ModLINK interface is: 

19,200 baud, 8-N-1

.

Alternate speeds and formats between 9,600 - 115,200 baud may be configured with the free AgrowLINK PC 

utility using a LX1 USB AgrowLINK and the cross-over adapter supplied with the LX2 ModLINK. 

MODBUS Manual

See MODBUS manual for more information.

LX2 ModLINK™

Technology to Help You Grow

AGROWtEK

U.S.A.

MADE IN

www.agrowtek.com

GrowNET

Device/Hub

TM

USB

AgrowLINK

TM

LX1 USB to GrowNET™ Bridge

TX

RX

 GrowNET

Cross-Over

  Adapter

LX1 USB AgrowLINK™

GrowNET™

Cross-Over

Adapter

7 - 24 Vdc

Technology to Help You Grow

AGROWtEK

U.S.A.

MADE IN

www.agrowtek.com

GrowNET

Device/Hub

TM

ModLINK

TM

LX2 MODBUS RTU Bridge

+7-24V

dc

GND A B

RJ45 CABLE

7 - 24 Vdc

Technology to Help You Grow

AGROWtEK

U.S.A.

MADE IN

© Arowtek Inc. | www.agrowtek.com

GrowNET
Link Port

MODBUS

TM

Digital Water Sensor
Logger & Controller

TEMPERATURE

CONDUCTIVITY

pH

O.R.P. / D.O.

 GrowControl

TM

pH

Probe

o.r.p./d.o.

Probe

Temp Probe | EC Probe
red blk wht | clr red blk

GPH MNU

H/L

72.0

45.2

123

455

°F

%

W/m

ppm

2

Technology to Help You Grow

AGROWtEK

GrowControl

TM

SXE

Environment Sensor

Data Logger

U.S.A.

MADE IN

© Agrowtek Inc.

www.agrowtek.com

WiFi

optional

GrowNET
Link Port

MDOBUS RTU

TM

WiFi

Reset

24Vdc in

4-20mA out

KEEP 
FAN
FILTER
CLEAN

GPH MNU

H/L

72.0

45.2

123

455

°F

%

W/m

ppm

2

Technology to Help You Grow

AGROWtEK

© 2016 Agrowtek Inc. | www.agrowtek.com

RD8

Equipment Control Interface

U.S.A.

MADE IN

DANGER! Risk of electric shock.

Disconnect all power sources before opening cover.

Read manual before installing or operating.

WiFi

Antenna

Programmable Smart Relays for Automation Control

1 2 3 4 5 6 7 8

AgrowNET
Link Port

TM

STATUS INDICATORS

GrowNET™ Devices

3.3/5Vdc Serial Bus Compatible.

Include required bus terminating resistors per EIA standard.

TX/RX+

TX/RX-

PLC

Technology to Help You Grow

AGROWtEK

U.S.A.

MADE IN

www.agrowtek.com

GrowNET

Device/Hub

TM

ModLINK

TM

LX2 MODBUS RTU Bridge

+7-24V

dc

GND A B

Technology to Help You Grow

AGROWtEK

U.S.A.

MADE IN

© Agrowtek Inc. | www.agrowtek.com

GrowNET™8-Port Hub

GrowControl™

1    2    3    4

8    7    6    5

12-24Vdc

GrowNET
Upstream
Port

TM

HX8

power

RS-485

Содержание GrowControl SXC

Страница 1: ...f reading 4 20mA DAC Resolution 12 bit 0 005mA Interface GrowNET MODBUS or WiFi Specifications Shown with optional WiFi Climate Sensor Data Logger Contents Installation Instructions 2 Connection to GC...

Страница 2: ...ded for installing against a vertical wall surface or a hanging bracket is avail able for conveniently suspending the sensor from a wire or cable in the middle of the environment Note the location of...

Страница 3: ...w AGROWtEK U S A MADE IN 2016 Agrowtek Inc www agrowtek com GrowControl SXC TM TEMP RH LIGHT CO2 if equippe d KEEP FAN FILTER CLEAN Sensor Mapping Sensors must be mapped in the controller so it knows...

Страница 4: ...erminals for the analog channels 4 20mA linear outputs correspond to the ranges in the specifications table Connection to 4 20mA Outputs 24VDC 4 20mA PLC ANALOG INPUTS PIN CONNECTION 1 24VDC 2 GND 3 C...

Страница 5: ...wNET Cross Over Adapter LX1 USB AgrowLINK GrowNET Cross Over Adapter 7 24 Vdc Technology to Help You Grow AGROWtEK U S A MADE IN www agrowtek com GrowNET Device Hub TM ModLINK TM LX2 MODBUS RTU Bridge...

Страница 6: ...n sends a positive or negative offset to the respective output channel s digital to analog converter DAC The DAC has a resolution of 0 005mA bit 1 calibration bit 0 005mA adjustment For example to shi...

Страница 7: ...gned Int 16 bit R 40104 Sensor 1 Value Sensor output Float 32 bit R 40201 Sensor 2 Value Sensor output Float 32 bit R 40203 Sensor 3 Value Sensor output Float 32 bit R 40205 Sensor 4 Value Sensor outp...

Страница 8: ...he cover 5 Locate the CO2 headers on the circuit board 6 Position and install the CO2 sensor module 3 ensuring the sensor is oriented with the correct pin head ers One header is 4 pins and the other i...

Страница 9: ...an air filter should be periodically removed for cleaning It is NOT necessary to remove the fan 1 Pry the retaining grate 1 out of the base 3 using a small flat blade eye glass screwdriver 2 Remove th...

Страница 10: ...Agrowtek Inc at no charge This warranty is provided in lieu of all other warranty provisions express or implied It is including but not limited to any implied warranty of fitness or merchantability f...