![Agromehanika AGP 1000 EN Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/agromehanika/agp-1000-en/agp-1000-en_manual_2870058045.webp)
USER MANUAL
43
03/2017
13.2
USE
Before starting the pump drive, make sure the main pressure regulator valve is in a free-flow position
(open tank return line).
Never turn on the pump’s drive when the setting on the regulator enables full stressing
of the pump.
Turn on the pump and let it run for approximately one minute under minimum pressure in order to
aerate the pump and the inlet and the outlet pipes. After one minute the pump is ready for operation.
Be careful not to exceed the maximum allowed pressure and the maximum allowed rpm of 550. On the
opposite, the manufacturer cannot be held responsible for any kind of damage that could occur.
13.3
AFTER USE
Some chemical agents can shorten the durability of some vital parts of the pump such as rubber
membranes and/or other rubber sealings. Therefore a thorough washing of the pump after every single
sprinkling is recommended. To do this, you will need to pump some clean water through the pump. Let
the pump operate at working pressure for several minutes. Lower the pressure and let the pump operate
for approximately one minute to blow out the rest of the liquid. During winter, leave all of the water
out of the pump and/or protect the pump against freezing (see chapter “Maintenance and storage after
use”).
13.4
TECHNICAL DATA
13.5
PUMP MAINTENANCE
OIL CHANGE
Always use the recommended oil only (see the above chart, or the pump registration plate, or the oil lid
on the pump itself).
PUMP IDENTIFICATION
PA 930
PBO 1250
FLOW QUANTITY
l/min
92,0
125,0
Max. OPERATING PRESSURE
bar
40
50
Max. ROTATIONS NUMBER
o/min
550
NEEDED POWER
kW
7,0
11,8
PRESSURE-MEMBRANE NUMBER
piece
3
MASS
kg
19,5
25,3
OIL
SAE
SAE 30
Oil max. level
Oil min. level