USER MANUAL
24
03/2017
9.5
MIXING NOZZLE
The sprayer is equipped with one or two mixing
nozzles for better mixing of the mixture. The
nozzles are mounted in the lower part of the
reservoir. The mixing nozzle is controlled by means
of the valve which is mounted on the pressure
regulator. The mixing nozzle is operating when the
lever of the valve is in upright position and vice-
versa. It is recommended to turn on the mixing
nozzle during insecticide preparation and driving to
the field.
9.6
THREE-WAY VALVE – EJECTOR (only AGP 1000 PE)
On the bottom side of the tank, simpler versions of the machine (with a pump capacity of up to 100
l/min and without an additional tank) are equipped with a three-way valve that has a cleaning filter
insert and a connector incorporated. The connector - through indirect help of the pump - enables the
ejector to suck water from lakes, ponds or other watercourses into the main tank.
FUNCTIONS OF THE THREE-WAY VALVE (SEE PICTURE)
1.
LEVER IN INTERNAL POSITION
In this lever position, the outflow of spray agent from the tank is stopped. It is possible to fill the tank
by placing the suction tube with basket
(020.20.018) on the suction fitting (019.01.032)
and the water will be drawn from low-lying
positions (stream, well). The suction tube with
suction basket is not part of the machine series
equipment.
2.
LEVER IN MIDDLE POSITION
The water outflow from the tank is enabled if the
three-way valve is positioned under the tank.
3.
LEVER COMPLETELY PULLED OUT
Normal functioning: the pump sucks water from
the tank through the cleaning insert in the three-way valve.
FILTER INSERT CLEANING
It is recommended to clean the cleaning insert of the three-way valve before each filling of the tank.
To reach the insert, pull the bolt (019.36.314) and the output insert (019.01.030). Wash the cleaning
filter insert under running water and place it back to its position in the ejector. The insert is point-
shaped, therefore make sure you insert it correctly – the wider part has to fit into the inside of the valve
body. If the cleaning insert has to be cleaned when the tank is full, push the lever in internal position
before dismantling to ensure that the outflow from the tank is closed.