Change engine oil
For the first time after 5
operating hours, then
after every
50
operating hours or
Yearly
(de-
pending on which occurs first). At heavy duty or
high ambient temperature, change the oil al-
ready after
25
operating hours. Change the oil
when the engine is still warm, but not hot -
dan-
ger of burns!
•
Clean oil filler plug / oil dipstick, oil drain
plug and their environment.
•
Open oil filler plug and oil drain plug, collect
the used oil in a suitable container. Alterna-
tively, you can use a drain pump to suck the
used oil through the filling hole.
•
Ensure proper disposal of the used oil.
Check the sealing rings. Replace if nec-
essary. Tighten the oil drain plug!
Oil filing volume and quality see "Technical da-
ta".
•
If possible, use a funnel or a similar fixture to
fill in the oil.
Air cooling system
After long periods of operation the cooling sys-
tem can be obstructed with dust or plant parti-
cles. Continuous operation with an obstructed
cooling system causes the engine to overheat
and can damage the engine.
Never spray water on the engine. Use a brush or
compressed air.
•
Continually check the
fan grille
(C/5), and
remove aspirated dirt and plant debris.
•
Remove the
fan housing
after every
100
operating hours or
at least yearly
, ideally
before the season. Clean the cooling fins on
cylinder and cylinder head, and the deflector
plates and the fan wheel that are necessary
for air circulation.
- agria-Service -
Содержание Bison 5900 Series
Страница 4: ...4 agria 5900 Bison Designation of parts Fig A Fig B...
Страница 18: ...2 Technical Data 18 Hydrostatic Implement Carrier agria 5900 Bison Wheel combinations track dimensions...
Страница 87: ...Hydrostatic Implement Carrier agria 5900 Bison 87 Declaration of Conformity...
Страница 89: ...agria 5900 Bison 89 Fig C Petrol engine...
Страница 91: ...agria 5900 Bison 91 Fig D Diesel engine...