32
agria-
Two-Wheel Tractor 2500 Hydro
31 Battery
34 Trailer socket (vers. petrol engine)
35 Flat plug-type fuse holder in the battery
box or trailer socket box (vers. petrol
engine)
31
34
35
Battery
(Version electric starter)
There is no dry pre-charging of batteries
on the new machines or trailers. Therefore
the battery must be filled with accumulator
acid and charged (charging current =1/10
of battery capacity).
Note manufacturer’s instructions!
Fuse
Vers. petrol engine
To protect the regulator and generator from
a short circuit induced from outside, a fuse
(35) is incorporated:
l
for the electric starter version in the
battery box
l
for the recoil starter version in the trai-
ler socket box.
Replace the fuse if it is defective. To do this,
open the fuse holder - ensure to provide
another spare fuse in time.
Fuse
Vers. diesel engine
A 15 amps fuse (D/26) is located between
the regulator and electric starter to protect
the regulator and generator from a short
circuit induced from outside.
Replace the fuse if it is defective. To do
this, remove the panel (23) and open the
protective bracket (D/25). Inside this
bracket you will find a spare fuse. Ensure
to provide another spare fuse in time.
3. Devices and Operating Elements
3