30
30 di 56
© AGREX S.p.A.
Computer PFI - Operator Manual
Work Preferences [1]
DISPLAY (page 1)
•
OPERATING MODE: the active operating mode, selectable from the
options MANUAL, SPEED, SEMI-AUTOMATIC and AUTOMATIC;
•
MAX. FLOW ERR.: in semi-automatic mode, the maximum % error
permitted during periodic recalibration of fertilizer flow;
•
FLOW CAL. AREA: in semi-automatic mode, the spread surface area
after which a message is displayed requesting recalibration;
•
EDGE KIT: edge kit installed or absent;
•
FIELD NO.: number identifying the field being fertilized;
•
PAGE NUMBER/TOTAL PAGES.
COMMANDS (page 1)
•
The buttons alongside the and , icons select the value of a
parameter from a pre-set list. Here, the operating mode.
The set value is confirmed by pressing
or waiting 3 seconds,
after which time the system displays the previous page.
•
The button alongside the icon displays a page where you can enter
numbers using the icons alongside the numbers and decimal point:
In the case of the MAX. FLOW ERR. parameter, by pressing the buttons
alongside the icons containing numbers you can enter up to 5 characters
to define the maximum % error permitted during periodic recalibration of
fertilizer flow in semi-automatic mode.
In the case of the FLOW CAL. AREA parameter, by pressing the buttons
alongside the icons containing numbers you can enter up to 5 characters
to define the maximum % error permitted during periodic recalibration of
fertilizer flow in semi-automatic mode.
The button alongside the
icon cancels the last character entered.
Holding it down cancels the entire value.
After entering the value, press the button alongside the
icon to
confirm and exit the menu or the button corresponding to the
icon to
exit the menu without confirming.
•
The buttons alongside the and icons activate or deactivate a function. Here, the
presence on the machine of an optional edge kit.
The set value is confirmed by pressing
or waiting 3 seconds, after which time the
system displays the previous page.
•
The buttons alongside the and icons display a page where you can configure the
values to be assigned to the parameter:
•
OPEraTing MOdE
OPEraTing MOdE
EdgE KiT
FLOW CaL. arEa
MaX. FLOW Err
FiELd nO.
MaX. FLOW Err.