Insert the 4 screws with the sensor plate
through the holes in the side wall and press the
sensor plate so to the press wall that the 4
small grommets slide into the holes.
If necessary, you can push it gently with a
small hammer. If you have drilled the holes
inaccurate, it is possible to drill again one or
more holes from 12 mm to 13 mm.
The sensor plate must be in contact uniformly
with the press wall without spacing, otherwise
there is the danger that stalks are pinched or
the sensor plate is torn.
Mount on the outside first one plastic spacer.
Then fit a washer on each bolt, a locking ring
and a hex nut.
Tighten the nuts with a spanner with a key
width of 13 mm. When tightening make sure
that the position of the square of the bolts
corresponds with the position of the square of
the sensor plate.
The sensor cable is assembled with the two
cable loops to 2 of the screws. Which cable is
mounted on which screw is not relevant. Use in
any case two screws next to each other.