7.3

 

Performing measurements 

 

Once the device is turned on, it is in the measurement mode and 

continuously displays moisture levels. These readings are only useful if 

compacted material is applied to the sensor.  

 

The device measures 25 times per second and calculates within the set 

display interval (1, 2, 5 or 15 seconds) an average of all measurements in 

this interval. This average value is displayed as a measured value.  

 

Moisture values are shown from 9 to 50 percent. 

 

At moisture levels below 9 %, the device displays the text "L" 

 

At moisture levels above 50 %, the moisture flashes with the text "H" 

 

The current display is signaled by the flashing decimal point. 

7.4

 

Setting the display interval 

The button [Interval] the duration of the display interval can be set in seconds. 

Possible values are 1, 2, 5 and 5 seconds. The set interval is displayed briefly, 

then the device automatically returns to the measuring mode. 

7.5

 

Forming manual averages 

To form an average of several displayed moisture values manually

 

, proceed as 

follows: 

 

Once a measured value is on the display briefly press the button [average]. 

The displayed measured value is written into the memory. On the display 

appears for 2 seconds the number of measurements that are already in 

memory. After that, the unit will return to the automatic display of the 

moisture.  

 

Repeat the process as many times as you like with different values in the 

same bale or measurements of several bales. 

Содержание PFM II

Страница 1: ...AGRETO electronics GmbH User Manual AGRETO PFM II Baler Mounted Moisture Meter 31 05 2017...

Страница 2: ...the sensor plate and the sensor cable 7 6 4 Installation of the display unit 9 7 Working with the device 11 7 1 Keypad 11 7 2 Switching on the device 11 7 3 Performing measurements 12 7 4 Setting the...

Страница 3: ...6 x stainless steel nuts 4 x nuts und 4 x plastic isolation discs 1 Manual 3 Intended use The AGRETO PFM II Baler mounted moisture meter is designed for measuring the moisture of hay and straw bales d...

Страница 4: ...read and understood this manual 4 2 Safety instructions for the operator DANGER The AGRETO PFM II may only be operated by persons who are familiar with the operation of the device CAUTION Keep the wor...

Страница 5: ...with the device or reside in the working area the wearing of safety shoes are required 4 4 Residual risks When using the device Residual hazards for persons and objects may occur that can t be prevent...

Страница 6: ...inuous display of the measured value during the pressing process Display of average values in adjustable intervals 1 2 5 or 15 seconds Manual averaging counting function Acoustic warning in case of to...

Страница 7: ...accessible for installation even from the outside If the pressed material is cut on one side mount the sensor on the other side where the material to be pressed is not cut 6 3 Installation of the sens...

Страница 8: ...contact uniformly with the press wall without spacing otherwise there is the danger that stalks are pinched or the sensor plate is torn Mount on the outside first one plastic spacer Then fit a washer...

Страница 9: ...ble location in the cab for mounting the display unit You can use the 6 holes in the bracket for mounting on a bracket a mounting panel or directly to a cab upright If you perform drilling operations...

Страница 10: ...and disconnect the sensor cable when attaching and deattaching the baling machine Pin assignment sensor cable If you dismount a connector on the sensor cable and need to re connect use the pin assign...

Страница 11: ...AGRETO electronics GmbH page 11 7 Working with the device 7 1 Keypad 7 2 Switching on the device Make sure that the sensor is connected and turn the power on by pressing the On Off button Light Interv...

Страница 12: ...e current display is signaled by the flashing decimal point 7 4 Setting the display interval The button Interval the duration of the display interval can be set in seconds Possible values are 1 2 5 an...

Страница 13: ...y To delete the total memory switch the device manually off and on again 7 8 Acoustic warning When the moisture measurement is over the set limit an acoustic signal sounds For setting the limit betwee...

Страница 14: ...e This fact is advantageous in practice in many cases as with more compressed bales increased sensitivity is advisable with respect to quality and storability 8 2 Material A hay or straw bale consists...

Страница 15: ...the power supply is upright and if the fuse in the power cable is okay 10 2 Incorrect measuring values If you have reason to believe that the displayed values are not correct please note the followin...

Страница 16: ...The warranty period begins with the first accounting to an end customer and ends 5 years from this date of invoice Prerequisite for warranty service are the presentation of the original invoice and co...

Страница 17: ...ation of the laws of Member States relating to electromagnetic compatibility 2004 108 EC For the evaluation regarding electromagnetic compatibility the following standards were applied EN 61000 6 1 20...

Страница 18: ...hnical changes or design changes All information in this manual are supplied without liability despite careful preparation A liability by the author is excluded Copyright 2017 AGRETO electronics GmbH...

Отзывы: