![AGP TC100 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/agp/tc100/tc100_original-operating-instructions_2869185010.webp)
10
When the cut is finished keep the motor running until the bit is removed from the cut to
avoid it getting stuck.
CAUTION: Drilling operations are very stressful to the motor and at the end of the cut, the
motor temperature will be very hot, always run the motor at no load for a few minutes until the
temperature returns to a normal range before shutting off. Turn the water feed down to a very
small amount of flow (not off), just enough to keep the water seals from overheating when you
perform this step.
Then turn off the switch, allow the coasting bit to stop, shut off the water supply.
To remove the machine from the work piece, shut off the vacuum pump. Disconnect the
vacuum hose coupling to release the vacuum seal.
WARNING: When the hose coupling is opened, the vacuum will be suddenly released.
If the vacuum base is mounted to a slanted surface and it is unsafe to allow a sudden loss of
vacuum, then first close the vacuum valve before removing the vacuum hose coupling. Then
the vacuum can be controllably released by slowly opening the valve.
SHARPENING A GLAZED BIT
If the bit becomes glazed, the ideal way to resharpen and true it up is by dressing with an
appropriate alumina oxide or silicon carbide dressing stick. Simply drill into the stick as many
times as necessary to restore its cutting performance.
If it is only slightly dull, while cutting, you may first reduce the water flow until the water
exiting the cut is really muddy.
If that still does not work the only choice is a dressing stick.
VIBRATION TROUBLESHOOTING
If vibration occurs and it is not caused by embedded steel, stop drilling to find the
cause and remedy.
CAUTION: Do not operate with vibration or there will be serious hazard and the diamond
core bit will surely be destroyed.
Vibration is usually caused by:
1.
A bit with too much runout
SOLUTION:
Replace bit.
2.
A bit with diamond segments broken off
SOLUTION:
Replace bit.
3.
Shifted vacuum base or loose gibs
SOLUTION:
Retighten mountings or adjust gibs as needed.