24
AGM Global Vision
MALFUNCTION
PROBABLE CAUSE/ TEST/
INSPECTION
CORRECTIVE ACTION
No image on an
external monitor.
Video cable is damaged.
Replace the video cable with a new
one. If this is not effective, please
contact Customer Support.
The equipment is damaged.
Please contact Customer Support.
Hindered rotation
of the battery cap.
Dirty cap thread.
Clean the thread.
Damaged cap thread.
Replace the cap with a new one. If
this is not effective, please contact
Customer Support.
Light is visible
around eyecup.
Check eyecup resilience.
If the eyecup is defective, please
contact Customer Support.
3.2 MAINTENANCE
3.2.1 GENERAL
The Asp operator maintenance consists of operational tests, inspections for unit serviceability,
cleaning and mounting procedures, and corrective actions (troubleshooting and replacement
of a limited number of parts). Maintenance instructions covered elsewhere in this manual
(troubleshooting, etc.) are not repeated in this section.
CAUTION:
The Asp is a precision electro-optical instrument and must be handled carefully at all times to
prevent damage.
CAUTION:
DO NOT dismantle the equipment.
3.2.2 CLEANING PROCEDURES
Clean the Asp and optional items as follows:
1. Gently brush off any dirt from the equipment using only a clean, soft cloth.
2. Moisten the cloth with fresh water and gently wipe the external surfaces (except for optical
surfaces).
3. Dry any wet surfaces (except for optical surfaces) with another clean, dry, soft cloth.
4. Using a lens brush, carefully remove all loose dirt from optical surfaces (objective lens and
eyepiece).
5. Dampen a cotton swab with ethanol and lightly and slowly wipe optical surface. Clean the
optical surface using circular movements, starting from the center and moving out towards the
edge, not touching the lens holder and changing the cotton swab after each circular stroke.
Repeat until the optical surface is clean.
6. Clean the battery contact surfaces and contact springs with a pencil eraser and/or alcohol and
cotton swabs.
CAUTION:
Thoroughly dry each item before replacing into the storage/ carrying case.
Содержание ASP
Страница 1: ...USER MANUAL ASP THERMAL IMAGING MONOCULAR...
Страница 31: ......