20
AGM Global Vision
2.3 OPERATING PROCEDURES
2.3.1 OPERATING
CAUTION:
DO NOT force the equipment controls past their stopping points.
CAUTION:
To prevent thermal damage to the equipment, never point it, either powered or not, directly at the
sun or any other source of high intensity light that the unprotected human eye cannot tolerate
(such as a welding arc). To prevent inadvertent exposure to these sources, never leave the
equipment without the objective lens cap secured.
Operating procedures are as follows:
1. Remove the Asp from the carrying case.
2. Remove the objective lens cap.
3. Point the equipment at an object.
4. Activate the Asp by turning the operation switch ON. After approximately 3 sec, video of the
thermal scene should appear.
5. Adjust the Asp for your eyesight by turning the eyepiece focus ring CW up to the stop, and then
CCW until the display and symbols are as clear as possible. Bring the object into focus by turning
the objective focus ring (CW for far focus, CCW for near focus).
NOTE:
The total diopter adjustment range is covered with 2 turns of the eyepiece focus ring.
The total focus range is covered with three quarter turns of the objective focus ring.
6. Using the buttons on the control panel (Figure 2-16), configure the Asp to adapt it to your
situation.
For more information on operational setting procedures, see Part 2.2 (Controls and Display
Indications).
FIGURE 2-16. SETTING BUTTONS
(1) BRIGHTNESS UP/
PALETTE (FWD)
(3) BRIGHTNESS DOWN /
PALETTE (BWD)
(4) RETICLE COLOR /
RETICLE PATTERN
(2) DIGITAL ZOOM /
RETICLE ON/ OFF