INFORMATION TO USER

 

 
This device complies with Part 15 of the FCC Rules.  Operation is subject to the 
following two conditions:  (1) This device may not cause harmful interference, and 
(2) This device must accept any interference received, including interference that 
may cause undesired operation. 
 
This equipment has been tested and found to comply with the limits for Class B 
Digital Device, pursuant to Part 15 of the FCC Rules.  These limits are designed 
to provide reasonable protection against harmful interference in a residential 
installation.  This equipment generates and can radiate radio frequency energy 
and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications.  However, there is no guarantee 
that interference will not occur in a particular installation.  If this equipment does 
cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures. 
 

• 

Reorient or relocate the receiving antenna 

• 

Increase the separation between the equipment and receiver 

• 

Connect the equipment into an outlet on a circuit different from that to which 
the receiver is connected 

• 

Consult the dealer or an experienced radio/TV technician for help 

 
Any changes or modifications not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment. 

------------ 

To comply with FCC RF exposure compliance requirements, a separation 
distance of at least 20 cm must be maintained between the antenna of this device 
and all persons. This device must not be co-located or operating in conjunction 
with any other antenna or transmitter. Do not install in a location such that this 
device will be within 20 cm of all persons. 
 
To comply with Industry Canada RF exposure compliance requirements, a 
separation distance of at least 20 cm must be maintained between the antenna of 
this device and all persons. This device must not be co-located or operating in 
conjunction with any other antenna or transmitter. Do not install in a location such 
that this device will be within 20 cm of all persons. For the hand held remote, do 
not transmit while close to the body or while in one’s pocket or holster.  
See Industry Canada RSS 102 for Radio Frequency (RF) Exposure Compliance 
of Radiocommunication Apparatus for exposure compliance. 

Содержание GradoPlane 15

Страница 1: ...GradoPlane 15 Operator s Manual Operation Instructions Mode d emploi Istruzioni per l uso...

Страница 2: ...ument 8 Entering a grade 8 Tilt Function 9 Rotation speed 9 Mask mode 9 Scan Mode 9 Manual Mode 10 Operation with the remote control 10 Change of batteries of the remote control 10 Special functios 11...

Страница 3: ...k with machine control units with rotation speed of 600 and 800 RPM The GradoPlane 15 instrument is waterproof and can be used outside in the elements An optional radio remote control is offered that...

Страница 4: ...tention Do not disassemble the instrument Inappropriate repairs can cause hazardous laser radiation Only AGL certified service centers are entitled to repair these products In the case of inappropriat...

Страница 5: ...separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV te...

Страница 6: ...hown while the charging procedure is active If the charging is finished the battery shows three full blocks The instrument has a charge controller inside so not to overcharge if the unit is not monito...

Страница 7: ...against vibrations in the Display MRS motion resistant system is shown Enters a grade in X and Y direction X Y button press once for X direction press again for entering the Y value Indications in the...

Страница 8: ...ade To enter a grade press the X Y button The instrument switches to the grade mode and the last used values are shown in the display When the work has to be done with these values just wait until the...

Страница 9: ...the rotation button The laser spot then can be moved with the arrow keys Mask mode In the mask mode the laser beam can be switched off in different sections This function is used to avoid interferenc...

Страница 10: ...opped in grade mode Tilt control the X Y and rotation button can be pressed simultaneously for 2 seconds to confirm and restart the laser If a V and three bars are shown there is no communication with...

Страница 11: ...Programm Version z B b 0709 12 1 3 Display Serial Number Press button for next step in the menu Rotation speed Max RPM Display 600 or 800 With Arrow keys choose max RPM 600 or 800 Button to store and...

Страница 12: ...rial number Display e g 135350 4 x Software Version Display e g 600527 5 x Com channel Display CH 1 17 With Arrow keys choose 0 to 17 FB2 default setting channel 1 Button to store and change to next m...

Страница 13: ...d Safety information Proper use The instrument is for aligning in the desired direction and the grade The instrument is used with a rechargeable NiMH battery The control of the instrument can be done...

Страница 14: ...14 Positions of laser warning labels JCS1 JCS2...

Страница 15: ...rking temperature 14 F 122 F 10 C 50 C Rotations speed 0 600 800 RPM Battery NiMH battery 12V DC current with optional cable Working hours 20 h Charging time maximum 5 hours Protection class IP67 wate...

Страница 16: ...pment The user is responsible for the regular checking of the instrument by the manufacturer or one of its authorized service center A calibration interval of one year is recommended The manufacturer...

Отзывы: