4
IMPORTANT SAFETY INFORMATION ABOUT
PROPANE (LP) GAS
A LP-gas cylinder for use with this appliance must have a capacity of 9kgs / 20 lbs.
and must be equipped with a Type 1 connector and an OPD (overfill protection
device). Figure 1
The LP-gas supply cylinder to be used must be constructed and marked in
accordance with the specification for LP-gas cylinders of the U.S. Department of
Transportation (DOT) or the National Standard of Canada,
CAN/CSA-B339,
Cylinder, Sphere and Tubes for the Transportation of Dangerous Goods
.
l
The cylinder supply system must be arranged for vapor withdrawal.
l
The cylinder used must include a collar to protect the cylinder valve.
l
This appliance shall be used only outdoors in a well-ventilated space and shall
not be used in a building, garage or any other enclosed space.
l
When this appliance is not in use, the gas must be turned off at the supply
cylinder.
l
Storage of this appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance.
l
Cylinders must be stored outdoors in a well-ventilated area out of the reach of
children. Disconnected cylinders must have threaded valve plugs tightly
installed and must not be stored in a building, garage or any other enclosed
areas.
CSA (Canadian Standards Association) certified to ANSI Z21.97-2014 / CSA
2.41-2014
“
Outdoor Decorative Gas Appliances
”
The gas hose is routed through a
“
U
”
bolt to prevent the hose from coming in contact
with the burner. DO NOT remove the hose from the
“
U
”
bolt. See Figure 2.
Figure 1
Figure 2
SPECIFICATIONS
INPUT
40,000 Btu/hr
30,000 Btu/hr Low fire
Propane Regulator
Pressure
2.74 / 11 in kpa water column
Natural Gas Minimum
Inlet Pressure
1.74 kpa / 7 in water column
Clearances to
combustible surfaces
60.96 cm / Sides 24 in
182.88 cm / Top: 72 in
Regulator hose
pointed down
Jul-01-2016