background image

Tilt Stand 

Tilt stand at 60°

Tilt stand at 30°

The Agilent U1241A and U1242A are safety-certified in compliance 
with the following safety and EMC requirements:

• IEC 61010-1:2001 / EN61010-1:2001

• USA: UL 61010-1:2004

• Canada: CSA C22.2 No. 61010-1:2004

• Category III 1000 V Overvoltage Protection

• IEC 61326:2002/EN 61326: 2003

• CISPR 11:1990/EN55011:1990

• Canada: ICES-001:2004

• Australia/New Zealand: AS/NZS CISPR11:2004

Safety Notices

C A U T I O N

CAUTION

 notice denotes a hazard. It calls attention to 

an operating procedure, practice, or the like that, if not 
correctly performed or adhered to, could result in damage 
to the product or loss of important data. Do not proceed 
beyond a 

CAUTION

 notice until the indicated conditions 

are fully understood and met.

WA RN I N G

WARNING notice denotes a hazard. It calls attention to 
an operating procedure, practice, or the like that, if not 
correctly performed or adhered to, could result in per-
sonal injury or death. Do not proceed beyond a WARN-
ING notice until the indicated conditions are fully 
understood and met.

Safety Symbols

CAT III
1000 V

Safety Information

Caution, risk of danger (refer to this manual 
for specific Warning or Caution information)

Caution, risk of electric shock

Earth (ground) terminal

Category III 1000 V Overvoltage Protection

For further safety information details, refer to the Agilent U1241A and U1242A Handheld Digital Multimeter 
User’s and Service Guide.

First Edition, July 20, 2007

©

Agilent Technologies, Inc. 2007

Printed in Malaysia

Agilent Technologies

U1241-90024

U1241A_U1242A_QSG_ENG_MY.fm  Page 4  Tuesday, July 3, 2007  2:23 PM

Содержание U1241A

Страница 1: ... 11A 1000 V 30 kA fast acting fuse Temperature T1 T1 1000 V R M S Temperature for U1242A T2 T2 440 mA 1000 V 30 kA fast acting fuse WARNING To avoid damaging this device do not exceed the input limit Keypad Annunciator Rotary Switch U1241A U1242A Input Terminal Agilent U1241A U1242A Handheld Digital Multimeter Quick Start Guide Agilent Technologies U1241A_U1242A_QSG_ENG_MY fm Page 1 Tuesday July 3...

Страница 2: ...ng mode and datalog viewing mode 6 AC or DC measurement mode 17 Secondary display temperature display 7 Auto range 18 Null math function 8 Diode Audible continuity 19 Thermocouple type for temperature measurement 9 T1 T2 and T1 T2 temperature measurements scan for U1242A 20 Primary measurement units 21 Measurement range 10 Data hold 22 Low battery indicator 11 T1 T2 and T1 T2 temperature measureme...

Страница 3: ... 440 mA mA scale DCA 0 001 A to 10 A ACA measurement 0 001 A to 10 A T1 T1 temperature 40 C to 1000 C T2 and T1 T2 temperature measurements for U1242A 40 C to 1000 C Actions Steps Turns ON backlight Press Checks battery capacity Press and hold for 1 second Freezes the measured value Press Starts MIN MAX AVG recording Press and hold for 1 second Offsets the measured value Press Scan the measured te...

Страница 4: ...the indicated conditions are fully understood and met WARNING WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in per sonal injury or death Do not proceed beyond a WARN ING notice until the indicated conditions are fully understood and met Safety Symbols CAT III 1000 V Safety Information Cau...

Отзывы: