Agilent Technologies TS-5410 Скачать руководство пользователя страница 3

Safety and Support Information

3

Safety Summary

The following general safety 
precautions must be observed 
during all phases of operation of 
this system. Failure to comply 
with these precautions or with 
specific warnings elsewhere in 
this manual violates safety 
standards of design, 
manufacture, and intended use 
of the system. Agilent 
Technologies, Inc. assumes no 
liability for the customer's 
failure to comply with these 
requirements.

General

This product is provided with a 
protective earth terminal. The 
protective features of this 
product may be impaired if it is 
used in a manner not specified 
in the operation instructions.

WARNING:

DO NOT OPERATE 

IN AN EXPLOSIVE ATMOSPHERE
Do not operate the system in the 
presence of flammable gases or 
flames.

If the equipment in this system 
is used in a manner not 
specified by Agilent 
Technologies, the protection 
provided by the equipment may 
be impaired. 

Cleaning Instructions

Clean the system cabinet using a 
soft cloth dampened in water.

WARNING:

DO NOT REMOVE 

ANY SYSTEM COVER
Operating personnel must not 
remove system covers. Component 
replacement and internal 
adjustments must be made only by 
qualified service personnel.
Equipment that appears damaged or 
defective should be made 
inoperative and secured against 
unintended operation until they can 
be repaired by qualified service 
personnel.

Environmental Conditions

Unless otherwise noted in the 
specifications, this system is 
intended for indoor use in an 
installation category II, 
pollution degree 2 environment. 
It is designed to operate at a 
maximum relative humidity of 
80% and at altitudes of up to 
2000 meters. Refer to the 
specifications tables for the ac 
mains voltage requirements and 
ambient operating temperature 
range.

Before applying power

Verify that all safety precautions 
are taken. Note the external 
markings described in 

“Safety 

Symbols and Regulatory 
Markings” 

on page 4

Содержание TS-5410

Страница 1: ...Agilent Technologies Agilent TS 5410 Compact Functional Test System Site Preparation and Installation Guide...

Страница 2: ...document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Governmen...

Страница 3: ...e protection provided by the equipment may be impaired Cleaning Instructions Clean the system cabinet using a soft cloth dampened in water WARNING DO NOT REMOVE ANY SYSTEM COVER Operating personnel mu...

Страница 4: ...y equipment in a locked cabinet is required to gain access to them Additionally the operator cannot have access to a conductive surface connected to any cable conductor High Low or Guard ASSURE THE EQ...

Страница 5: ...letely disconnected from ac mains when this switch is off To completely disconnect the unit from ac mains either disconnect the power cord or have a qualified electrician install an external switch Re...

Страница 6: ...vice on the Web http www agilent com Click the link to Test Measurement Select your country from the drop down menus The Web page that appears next has contact information specific for your country Ag...

Страница 7: ...7 Doc Placeholder Page...

Страница 8: ...8...

Страница 9: ...ticulate Contaminants 15 Viscid Contaminants 15 Cooling Requirements 16 The Site Plan Drawing 17 AC Power Requirements 18 Important Information 18 Alternate Disconnect Recommendation 19 Optional Emerg...

Страница 10: ...10 Contents...

Страница 11: ...4 Environmental Requirements page 15 The Site Plan Drawing page 17 AC Power Requirements page 18 Alternate Disconnect Recommendation page 19 System Intended Use Agilent E22xxA systems are designed to...

Страница 12: ...t Load Box Other Mass Connect 5 10 DCV 0 74 m 0 6 m 0 75 m 0 06 m DC Fan Assy FRONT REAR PC PC Interconnect AC Power Mass Connect AC Power 34401A DMM 53131A Counter 33220A Arb Other 3499A B Switch Con...

Страница 13: ...ge of the crated system The crated system requires the use of a floor jack or fork lift to engage the pallet and lift the crated system The dimensions of the system crate including pallet are 41 inche...

Страница 14: ...rack is secured to the pallet of the shipping crate and wrapped with a plastic wrap Do not move the crate or the test rack and pallet to a static sensitive area until you have removed the plastic wra...

Страница 15: ...al are complex and costly If the source of corrosive contaminants cannot be eliminated the system should be installed in an enclosed environment with a fresh air supply at positive pressure Particulat...

Страница 16: ...ce the switch marked Fan Switch Only can be switched off during maintenance when the rack side panels and top are removed To prevent equipment damage from overheating the fans should be turned on at a...

Страница 17: ...If the operator will be positioned in front of the system allow 1 meter 3 3 feet of space in front of the system You should allow 1 meter 3 3 feet of space behind the system for service The 0 75 mete...

Страница 18: ...endations The system is to be supplied from a dedicated 15 16 Amp single phase service at the voltage for which the system is configured The system is delivered with a mating power connector for the s...

Страница 19: ...ndation Emergency power off EMO capability is not provided with the Filtered Power Strip An external mains disconnect switch or breaker should be installed adjacent to the equipment for easy access Us...

Страница 20: ...20 Site Preparation Chapter 1...

Страница 21: ...nd how to backup the system software Chapter contents are Grounding and Connecting Power to the System page 22 PC and Peripheral Connections page 25 Fixture and UUT Connections page 27 Getting Started...

Страница 22: ...position Lower the test rack leveling feet to stabilize the rack and prevent it from rolling 2 Make a permanent connection from the system rack to protective earth ground This connection will serve a...

Страница 23: ...minated power cord Wiring information for this cord is shown in Figure 2 3 Figure 2 1 Safety Ground Connections SystemRack T oothed Washers WireLug Earth ground terminal Protective Earth connection at...

Страница 24: ...g type needed and if necessary the power cord needed Make the appropriate connections between the cord and wall outlet connector and the Power Connector 5 Set the power switch on the top front of the...

Страница 25: ...ral Connections For your convenience PC connections have been brought out to the rear of the system on the PC and GPIB Connector Panel Figure 2 5 1 Connect the monitor keyboard mouse LAN and any USB o...

Страница 26: ...setting the front panel on off switch to ON Note DO NOT secure the AC power cord to the cable strain relief bracket such that it would prevent the plug from being removed from the power strip in an e...

Страница 27: ...d mark can be seen on the breaker switch Press the breaker button to reset Fixture and UUT Connections The Test System Interface on the front of the system allows you to make connections between the t...

Страница 28: ...luded with your system This guide shows you how to make connections to the system s Test System Interface This manual is also available from Test Exec SL by clicking Tools TS 5400 Online Manuals This...

Страница 29: ...power to the system 22 H Hallway and Door Width Requirements 13 Hole for routing wires 25 Humidity Requirements 16 I IEC320 C19 connector 23 If the system cannot be moved in the crate 13 K Keyboard 25...

Страница 30: ...k 12 Site plan 17 Static precautions 14 System Power Options 19 System Weight 13 T Temperature Requirements 16 Top view rack 12 Typical Power Plug Connections 23 Typical test system layout overhead vi...

Отзывы: