Agilent Technologies G4319A Скачать руководство пользователя страница 10

Notices

© Agilent Technologies, Inc. 2003

No part of this manual may be reproduced in 
any form or by any means (including electronic 
storage and retrieval or translation into a 
foreign language) without prior agreement and 
written consent from Agilent Technologies, 
Inc. as governed by United States and 
international copyright laws.

Manual Part Number

G4319-90000

Edition

First edition, July 2003

Printed in China

Agilent Technologies, Inc.
412 Ying Lun Road 
Waigaoqiao Free Trade Zone
Shanghai, 200131 P. R. China

Safety Notices

C A U T I O N

CAUTION

 notice denotes a hazard. 

It calls attention to an operating 
procedure, practice, or the like that, 
if not correctly performed or adhered 
to, could result in damage to the 
product or loss of important data. 
Do not proceed beyond a 

CAUTION

 

notice until the indicated conditions 
are fully understood and met.

WA R N I N G

A WARNING notice denotes a 
hazard. It calls attention to an 
operating procedure, practice, or 
the like that, if not correctly 
performed or adhered to, could 
result in personal injury or death. 
Do not proceed beyond a WARNING 
notice until the indicated 
conditions are fully understood and 
met.

Agilent Technologies

G4319-90000

Содержание G4319A

Страница 1: ...ector must be removed and replaced To achieve a standard factory configuration the TCD must be located in the front detector position If you are installing a new FID at this time refer to its installa...

Страница 2: ...or assembly Swage nuts and ferrules Tools Electrostatic protection such as a grounded wrist strap T 20 Torx screwdriver 7 16 inch wrench Steps 1 Preparing the GC 2 Raising the TCD Block 3 Adjusting Ve...

Страница 3: ...and then sliding the cover to the left to free its right hinge pin Perform this procedure only if necessary to add a new detector or to remove and replace an existing detector Remove the panels indic...

Страница 4: ...off 3 Remove the back panel by removing two screws at its bottom edge loosening two screws at its top edge and the lifting off the two top screws 4 Finally remove the rear top cover by removing four s...

Страница 5: ...ion Guide TCD to FID Series Connection 5 3 Cap the vent tube at the top of the detector Thermal cover Insulation Delta PRT sensor Vent tube Heater and PRT Vent tube support Retaining screw Detector ba...

Страница 6: ...installed into the top of the oven remove the retaining screw securing the vent tube support and remove the support 2 Carefully bend the vent tube downwards to be alongside the detector column make up...

Страница 7: ...to pack around the bottom and sides of the detector The goal is to fill all voids around the detector body as it is placed into the cavity 6 Remove caps from the detector base and from the vent tube...

Страница 8: ...t and Vespel ferrule to install the 1 4 to 1 8 inch adapter into the FID 3 Again following proper swaging procedures use the 1 8 inch brass tubing nut back ferrule and front ferrule to connect the TCD...

Страница 9: ...tion Guide TCD to FID Series Connection 9 4 Restore gas supplies and following leak test procedures described in the Maintenance and Troubleshooting manual check for leaks particularly at all new conn...

Страница 10: ...hai 200131 P R China Safety Notices CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could resu...