Product Warranty

This Agilent Technologies 
product has a warranty against 
defects in material and 
workmanship for a period of one 
year from date of shipment.  
During the warranty period, 
Agilent Technologies will, at its 
option, either repair or replace 
products that prove to be 
defective.

For warranty service or repair, 
this product must be returned 
to a service facility designated 
by Agilent Technologies.

For products returned to 
Agilent Technologies for 
warranty service, the Buyer 
shall prepay shipping charges to 
Agilent Technologies and 
Agilent Technologies shall pay 
shipping charges to return the 
product to the Buyer.  However, 
the Buyer shall pay all shipping 
charges, duties, and taxes for 
products returned to Agilent 
Technologies from another 
country.

Agilent Technologies warrants 
that its software and firmware 
designated by Agilent 
Technologies for use with an 
instrument will execute its 
programming instructions when 
properly installed on that 
instrument.  Agilent 
Technologies does not warrant 
that the operation of the 
instrument software, or 
firmware will be uninterrupted 
or error free.

Limitation of Warranty

The foregoing warranty shall not 
apply to defects resulting from 
improper or inadequate 
maintenance by the Buyer, 
Buyer- supplied software or 
interfacing, unauthorized 
modification or misuse, 
operation outside of the 
environmental specifications for 
the product, or improper site 
preparation or maintenance.

No other warranty is 
expressed or implied.  Agilent 
Technologies specifically 
disclaims the implied 
warranties of merchantability 
or fitness for a particular 
purpose.

Exclusive Remedies

The remedies provided herein 
are the buyer’s sole and 
exclusive remedies.  Agilent 
Technologies shall not be liable 
for any direct, indirect, special, 
incidental, or consequential 
damages, whether based on 
contract, tort, or any other legal 
theory.

Assistance

Product maintenance 
agreements and other customer 
assistance agreements are 
available for Agilent 
Technologies products. For any 
assistance, contact your nearest 
Agilent Technologies Sales 
Office.

Certification

Agilent Technologies Company 
certifies that this product met 
its published specifications at 
the time of shipment from the 
factory.  Agilent Technologies 
further certifies that its 
calibration measurements are 
traceable to the United States 
National Institute of Standards 
and Technology, to the extent 
allowed by the Institute’s 
calibration facility, and to the 
calibration facilities of other 
International Standards 
Organization members.

About this edition

This is the 

 E8041A IA-32 

478-Pin Interposer 
Installation Quick Start 
Guide

.

Publication number
E8041-92001,  October, 2001
Printed in USA.

Print history:

E8041-92000, restricted version

Many product updates do not 
require manual changes, and 
manual corrections may be done 
without accompanying product 
changes. Therefore, do not 
expect a one-to-one 
correspondence between 
product updates and manual 
updates.

Manual Part Number 

E8041-92001 

October 2001, Printed in USA

*E8041-92001*

*E8041-92001*

Содержание E8041A Interposer

Страница 1: ...Agilent Technologies E8041A Interposer for the Intel Pentium 4 Processor in the 478 Pin Package Interposer Installation Quick Start ...

Страница 2: ...rocessor and target system DO exercise patience and care when working with the interposer DO use ESD precautions DO remove power from the target system and analysis probe before making attachments DO protect the pins from damage by covering them with the pin protector when the interposer is not in use DO NOT insert any kind of tool between the interposer and the microprocessor except as described ...

Страница 3: ...oser Quick Start 3 1 Remove the heatsink from the microprocessor 2 Remove the microprocessor from the target system 3 Remove the Intel retention module from the target system 4 Install the Agilent retention modules ...

Страница 4: ...ck that the socket on the target system is still open 6 Remove the pin protector from the interposer Keep the pin protector You will need it to prevent damage to the interposer whenever the interposer is not plugged into the target system ...

Страница 5: ...target system This is done so that the interposer will not interfere with the target socket s actuation mechanism The wings of the interposer will flex around the retention modules 8 Gently wiggle the interposer until you feel the pins fall into the holes of the socket 9 Visually check that the bottom of the interposer is flush with the top of the socket on the target system ...

Страница 6: ... feel the pins fall into the holes Visually check that the bottom of the processor module is flush with the top of the socket on the interposer CAUTION The processor should be oriented the same way that it was originally oriented on the target system Note that the orientation of the processor with respect to the lever on the socket is opposite from the target system The socket is keyed so the proc...

Страница 7: ...E8041A Interposer Quick Start 7 13 Apply light downward pressure on the processor while you close the interposer socket 14 Re install the heatsink ...

Страница 8: ...8 E8041A Interposer Quick Start 15 Install the clip assembly to hold the heatsink in place Use the clip assembly which you removed earlier ...

Страница 9: ... labels on the interposer and on the cable paddles Install the supplied clips to keep the paddles on the end of the analysis probe cables from pulling apart 17 Connect the analysis probe to the logic analyzer Connect the pod cables to the connectors on the analysis probe as shown on the back of the analysis probe ...

Страница 10: ...10 E8041A Interposer Quick Start ...

Страница 11: ...earth contact You must not negate the protective action by using an extension cord power cable without a protective conductor grounding Grounding one conductor of a two conductor outlet is not sufficient protection Only fuses with the required rated current voltage and specified type normal blow time delay etc should be used Do not use repaired fuses or short circuited fuseholders To do so could c...

Страница 12: ...aration or maintenance No other warranty is expressed or implied Agilent Technologies specifically disclaims the implied warranties of merchantability or fitness for a particular purpose Exclusive Remedies The remedies provided herein are the buyer s sole and exclusive remedies Agilent Technologies shall not be liable for any direct indirect special incidental or consequential damages whether base...