68
Soft Touch Pro User’s Guide
5
Circuit Board Design
to appropriate pins on the probe connector. Refer to
"Triggering with the Agilent 1675x and 1676x" (Agilent
publication number 5988- 2994EN) for more details.
Half-channel 1.25 and 1.5 Gb/s modes
(16760A only)
In the half- channel 1.25 and 1.5 Gb/s modes, the 16760A
analyzer accesses only the even channels (0,2,4, etc.). In the
Format user interface, only the even data bits will be
connected to the analyzer.
Note that in the 1.25 and 1.5 Gb/s half- channel mode, the
clock inputs cannot be assigned as bits in a label.
E5386A Half-channel Adapter
The E5386A can be used with
the E5405A- pro series differential soft touch probe or the
E5402A/E5406A- pro series single- ended probes to map the
signals from the PC board pads to the 16760A when
operating in half- channel state mode.
Figure 47
E5386A Half-channed adapter