VOLTage Subsystem Introduction
VOLTage Subsystem Introduction
The VOLTage subsystem sets parameters related to output voltage.
Example
The following is a typical procedure using the VOLTage subsystem.
1.
Select the waveform shape, amplitude and offset:
Use
or the equivalent
,
, and
commands to select the function, frequency, amplitude, and offset.
2.
Set units for output amplitude:
3.
Set output amplitude:
4.
Set DC offset voltage:
5.
Set high and low voltage level:
and
6.
Select output voltage limits to protect device under test (DUT):
,
, and
7.
Select status of auto-ranging for all output functions:
8.
Set voltage coupling to lock amplitude and offset of the channels together:
This code demonstrates the procedure outlined above:
SOURce1:FUNCtion SQU
SOURce1:FRE1.0E+06
SOURce1:V0.5
SOURce1:VOLTage:0.5
SOURce1:FUNCtion:SQUare:1.0E-06
SOURce1:FUNCtion:PULSe:1.0E-06
SOURce1:VOLTage:LIMit:LOW +0.0
SOURce1:VOLTage:LIMit:HIGH +1.0
SOURce1:VOLTage:LIMit:STATe 1
OUTP1 ON
SOURce2:FUNCtion SIN
SOURce2:FRE1.0E+06
SOURce2:V2.0
SOURce2:VOLTage:0.0
SOURce2:VOLTage:LIMit:LOW -1.0
SOURce2:VOLTage:LIMit:HIGH +1.0
SOURce2:VOLTage:LIMit:STATe 1
OUTP2 ON
[SOURce[1|2]:]VOLTage {<
amplitude
>|MINimum|MAXimum}
[SOURce[1|2]:]VOLTage? [{MINimum|MAXimum}]
Sets output amplitude.
320
Agilent 33500 Series Operating and Service Guide
Содержание Agilent 33500 Series
Страница 1: ...Agilent Technologies 33500 Series Waveform Generator Operating and Service Guide ...
Страница 68: ...Output Configuration OUTPUT SYNC SOURCE CH1 CH2 Agilent 33500 Series Operating and Service Guide 67 ...
Страница 410: ...Block Diagram Block Diagram Agilent 33500 Series Operating and Service Guide 409 ...
Страница 429: ......