![Agilent Technologies 622Vu Advisor Скачать руководство пользователя страница 167](http://html.mh-extra.com/html/agilent-technologies/622vu-advisor/622vu-advisor_user-manual_2867918167.webp)
Use the drop-down lists in the mini-wizard to specify the Segmentation and
Reassembly (SAR) settings you want. The first position in the payload is
reserved for these (combined) settings and changes as you set each field:
Field
Description
CSI
Convergence Sublayer Indicator, specified as 0 or 1.
SC
Sequence count, in the range 0–7.
SN
Serial number, specified as hexadecimal 0–F. This value is carried in the high-order
four bits of the first payload byte. As an alternative to specifying this field, provide
the CSI and SC values individually.
CRC
Checksum of the unframed payload data, in the range 0–7. AAL1 uses this CRC to
verify correct transmission of the payload.
Parity
Parity used for transmission, specified as 0 (even) or 1 (odd).
SNP
Sequence Number Protection, specified as hexadecimal 0–F. This value is carried in
the low-order four bits of the first payload byte. As an alternative to specifying this
field, provide the CRC and Parity values individually.
AAL5 Framing
If you select AAL5 cell framing, 622Vu Advisor provides mini-wizards to assist
you in formatting the cell’s Segmentation and Reassembly (SAR), CPCS
(Common Part Convergence Sublayer), and time-stamp (Special) information
correctly.
Each has its own tab. Click each tab in turn, specifying information as described
below.
SAR Settings
There’s one SAR field. That field applies if this cell contains the end-of-
datagram signal (i.e., if it’s the last cell of the PDU):
9: Editing Transmit Sequences
9.4 Defining the Cells In a Sequence
167
Содержание 622Vu Advisor
Страница 1: ...Agilent Technologies 622Vu Advisor User s Guide ...
Страница 6: ...vi ...
Страница 54: ...3 Getting Started 3 4 Setting Up User Profiles 54 ...
Страница 66: ...4 Configuring Analysis Devices 4 2 Configuring an OC 12c STM 4c Device 66 ...
Страница 116: ...6 Capturing Incoming Traffic 6 3 Viewing Captured Traffic 116 ...
Страница 130: ...7 Monitoring Real Time Statistics 7 4 Creating A FilterSet That Captures Specific VCCs 130 ...
Страница 152: ...8 Filtering Captures 8 6 Advanced Filtering Mode 152 ...
Страница 180: ...10 Running Editing Scripts 10 2 Creating or Editing a Script 180 ...
Страница 224: ... A Glossary 224 ...
Страница 228: ...C Summary of Libraries 228 ...
Страница 230: ...230 ...
Страница 233: ...Declaration of Conformity 233 ...
Страница 234: ...234 ...
Страница 244: ...244 ...