Appendix Service Information
Constant Current (CC) Verifications
185
Se
rv
ic
e
In
fo
rm
a
tio
n
Constant Current (CC) Verifications
Constant Current Test Setup
Follow the general setup instructions in the General Measurement Techniques‚
on page 178, and the specific instructions will be given in the following
paragraphs.
Current Programming and Readback Accuracy
This test verifies that the current programming and GPIB or RS-232 readback
functions are within specifications. Note that the readback values over the
remote interface should be identical to those displayed on the front panel. The
accuracy of the current monitoring resistor must be 0.01% or better.
You should program the power supply over the remote interface for this test
to avoid round off errors.
1 Turn off the power supply and connect a 0.01
Ω
current monitoring resistor
(R
M1
) across the output to be tested and a digital voltmeter across the current
monitoring resistor (R
M1
) as shown in Figure A-1.
2 Turn on the power supply. Select the output to be tested and the low voltage
range (8V/3A)
†
and then enable the output by sending the commands:
INST:SEL {OUT1|OUT2}
VOLT:RANG P8V
(E3646A model)
OUTP ON
3 Program the output voltage to full scale rated voltage (8.0 V)
†
and output
current to zero amps by sending the commands:
VOLT 8
(E3646A model)
CURR 0
4 Divide the voltage drop (DVM reading) across the current monitoring resistor
(R
M
) by its resistance to convert to amps and record this value (I
O
). This value
should be within the limit of (0 A ± 10 mA). Also, note that the
CC
,
Adrs
,
Limit
,
and
Rmt
annunciators are on.
5 Readback the output current over the remote interface by sending the
command:
MEAS:CURR?
†
For E3646A model, and see
for other models
Содержание 2110-0457
Страница 9: ...8...
Страница 15: ...14 Contents Contents...
Страница 16: ...1 Quick Start...
Страница 26: ...2 General Information...
Страница 38: ...3 Front Panel Operation and Features...
Страница 70: ...4 Remote Interface Reference...
Страница 122: ...5 Error Messages...
Страница 133: ...Chapter 5 Error Messages Calibration Errors 132...
Страница 134: ...6 Application Programs...
Страница 145: ...Chapter 6 Application Programs Example Program for Excel 97 144...
Страница 146: ...7 Tutorial...
Страница 157: ...Chapter 7 Tutorial Remote Programming 156...
Страница 158: ...8 Specifications...
Страница 165: ...Chapter 8 Specifications Supplemental Characteristics 164 Figure 8 2 Dimensions for Rack mounting...
Страница 166: ...Appendix Service Information...
Страница 175: ...Appendix Service Information General Disassembly 174 General Disassembly...
Страница 202: ......
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 209: ...208 Index Index...