background image

Safety

Summary

The

following

general

safety

precautions

must

be

observed

during

all

phases

of

operation,

service

,

and

repair

of

this

instrument.

F

ailure

to

comply

with

these

precautions

or

with

specic

W

ARNINGS

elsewhere

in

this

manual

may

impair

the

protection

provided

by

the

equipment.

In

addition

it

violates

safety

standards

of

design,

manufacture

,

and

intended

use

of

the

instrument.

The

A

gilent

T

echnologies

assumes

no

liability

for

the

customer's

failure

to

comply

with

these

requirements

.

DO

NOT

Operate

In

An

Explosive

Atmosphere

Do

not

operate

the

instrument

in

the

presence

of

ammable

gasses

or

fumes

.

Operation

of

any

electrical

instrument

in

such

an

environment

constitutes

a

denite

safety

hazard.

K

eep

A

way

From

Live

Circuits

Operating

personnel

must

not

remove

instrument

covers

.

Component

replacement

and

internal

adjustments

must

be

made

by

qualied

maintenance

personnel.

Do

not

replace

components

with

the

power

cable

connected.

Under

certain

conditions

,

dangerous

voltages

may

exist

even

with

the

power

cable

removed.

T

o

avoid

injuries

,

always

disconnect

power

and

discharge

circuits

before

touching

them.

DO

NOT

Service

Or

A

djust

Alone

Do

not

attempt

internal

service

or

adjustment

unless

another

person,

capable

of

rendering

rst

aid

and

resuscitation,

is

present.

DO

NOT

Substitute

P

arts

Or

Modify

Instrument

Because

of

the

danger

of

introducing

additional

hazards

,

do

not

install

substitute

parts

or

perform

unauthorized

modications

to

the

instrument.

Return

the

instrument

to

a

Agilent

T

echnologies

Sales

and

Service

Oce

for

service

and

repair

to

ensure

that

safety

features

are

maintained.

Dangerous

Procedure

W

arnings

W

arnings

,

such

as

the

example

below

,

precede

potentially

dangerous

procedures

throughout

this

manual.

Instructions

contained

in

the

warnings

must

be

followed.

W

arning

Dangerous

voltages

,

capable

of

causing

death,

are

present

in

this

instrument.

Use

extreme

caution

when

handling,

testing,

and

adjusting

this

instrument.

Safety

Symbols

General

denitions

of

safety

symbols

used

on

equipment

or

in

manuals

are

listed

below

.

This

W

arning

sign

denotes

a

hazard.

It

calls

attention

to

a

procedure

,

practice

,

condition

or

the

like

,

which,

if

not

correctly

performed

or

adhered

to

,

could

result

in

injury

or

death

to

personnel.

This

Caution

sign

denotes

a

hazard.

It

calls

attention

to

a

procedure

,

practice

,

condition

or

the

like

,

which,

if

not

correctly

performed

or

adhered

to

,

could

result

in

damage

to

or

destruction

of

part

or

all

of

the

product.

Note

denotes

important

information.

It

calls

attention

to

a

procedure

,

practice

,

condition

or

the

like

,

which

is

essential

to

highlight.

iii

Содержание 16089E

Страница 1: ...Agilent 16089E Kelvin Clip Leads Operation Note Agilent Part No 16089 90001 Printed in JAP AN May 2000...

Страница 2: ...by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of the Agilent Technologies Agilent Tec...

Страница 3: ...ss another person capable of rendering rst aid and resuscitation is present DO NOT Substitute Parts Or Modify Instrument Because of the danger of introducing additional hazards do not install substitu...

Страница 4: ...ucts returned to Agilent Technologies from another country Agilent Technologies warrants that its software and rmware designated by Agilent Technologies for use with an instrument will execute its pro...

Страница 5: ...LCR meters and impedance analyzers 4263B 4278A 4284A 4285A 4192A 4194A The 16089E makes it possible to measure odd shaped components that cannot be measured with conventional test xtures The 16089E c...

Страница 6: ...onnected or disconnected Protect them from ESD damage by wearing a grounding strap that provides a high resistance path to ground Alternatively ground yourself to discharge any static charge built up...

Страница 7: ...Temperature 0 to 55 C Operating Humidity 95 RH 40 C Non operating Temperature 040 to 70 C Non operating Humidity 95 RH 40 C Cable Length approximately 1 m 1 Except for the frequency range over 100 kH...

Страница 8: ......

Страница 9: ...notify the carrier and Agilent Technologies Your Agilent Technologies sales o ce will arrange for repair and replacement without waiting for the claim to be settled 1 Inspect the shipping container fo...

Страница 10: ...ensing Packaging the Test Leads If shipment to a Agilent Technologies service center is required each test lead set should be repackaged using the original factory packaging materials Alteratively com...

Страница 11: ...h setting to 1 m 2 Connect the 16089E to the instrument s UNKNOWN terminals Figure 2 2 Connecting the Test Leads 3 Perform the OPEN and SHORT compensation as described in the instrument s operation ma...

Страница 12: ...on measurement accuracy the instrument s OPEN and SHORT compensation capabilities must be used The procedures are described in the instrument s operation manual Figure 2 3 Making a Shorting Condition...

Страница 13: ...ope Agilent Technologies Test Measurement European Marketing Organization P O Box 999 1180 AZ Amstelveen The Netherlands tel 31 20 547 9999 Japan Agilent Technologies Japan Ltd Call Center 9 1 Takakur...

Отзывы: