3. A
SSEMBLY
W
HEATHEART
- X-S
ERIES
13" A
UGERS
3.10. A
UGER
T
UBE
T
RUSS
A
SSEMBLY
X130-74, X130-84, X130-94
48
30787 R2
I
NSTALL
X130-84/X130-94 C
ABLE
T
RUSSING
See Table 3.10. for a list of parts required to install the X130-84/X130-94 truss
cables, as well as for figure references that apply to the Figure 3.18 (X130-84
shown, X130-94 is similar).
1. Attach eyebolts to both ends of a truss cable with two 3/8” cable clamps using
about 10" (25.4 cm) - 12" (30.5 cm) of cable. Tighten securely.
2. Thread the cable through the cable return bracket on the underside of the
lower tube, and pull the cable through until there is an equal length of cable
on each side of the tube. Secure the cable to the cable return bracket with a
5/16” cable clamp.
3. Insert the cable eyebolts into separate turnbuckle bodies and secure with 1/2”
locknuts threaded fully onto the eyebolt shaft, but not further than 1/4”.
4. Attach eyebolts to the unconnected ends of both turnbuckle bodies, and
secure with 1/2” locknuts threaded fully onto the eyebolt shaft, but not further
than 1/4”.
5. Thread the second cable through the cable return bracket on the underside of
the upper tube, and pull the cable through until there is an equal length of
cable on each side of the tube.
6. Pull the ends of both cables over the truss cable supports, loosely attaching
the truss cables to each truss cable support with a 5/16” cable clamps.
7. Thread the unconnected ends of the second cable through the unconnected
eyebolts on the turnbuckle bodies, pull tight, and then secure with two
3/8” cable clamps. Tighten securely.
8. Tighten the cables by adjusting the eyebolt locknuts. These cables must be
very tight.
9. Tighten the 5/16” cable clamps at the lower tube and upper tube cable return
brackets.
10. If the tube has a curve to one side, tighten the turnbuckle on the opposite
side, while loosening the other turnbuckle slightly if required.
11. Tighten the cable clamps on all cable supports and arms.
Table 3.10. Parts Required, X130-84 and X130-94 Truss Cables
Fig Ref
Part #
Part Description
X130-84
X130-94
1
19331
17750
Eyebolt
1/2” locknut
4
4
4
4
2
18990
3/8” cable clamp
8
8
3
20085
17576
70’ Cable
80’ Cable
2
--
--
2
4
n/a
Lower tube cable return bracket
1
1
5
19333
5/16” cable clamp
16
18
6
17464
Turnbuckle
2
2
7
n/a
Upper tube cable return bracket
1
1
8
n/a
Truss cable supports
7
7
Содержание WHEATHEART X Series
Страница 6: ...WHEATHEART X SERIES 13 AUGERS X130 74 X130 84 X130 94 6 30787 R2 ...
Страница 12: ...1 INTRODUCTION WHEATHEART X SERIES 13 AUGERS 1 1 OVERVIEW X130 74 X130 84 X130 94 12 30787 R2 ...
Страница 24: ...2 SAFETY WHEATHEART X SERIES 13 AUGERS 2 10 SAFETY DECALS X130 74 X130 84 X130 94 24 30787 R2 ...
Страница 78: ...3 ASSEMBLY WHEATHEART X SERIES 13 AUGERS 3 20 AUGER TO TRACTOR HOOKUP X130 74 X130 84 X130 94 78 30787 R2 ...
Страница 100: ...6 OPERATION WHEATHEART X SERIES 13 AUGERS 6 3 OPERATING PROCEDURES X130 74 X130 84 X130 94 100 30787 R2 ...
Страница 114: ...7 MAINTENANCE WHEATHEART X SERIES 13 AUGERS 7 3 MAINTENANCE PROCEDURES X130 74 X130 84 X130 94 114 30787 R2 ...
Страница 116: ...8 STORAGE WHEATHEART X SERIES 13 AUGERS X130 74 X130 84 X130 94 116 30787 R2 ...
Страница 118: ...9 TROUBLESHOOTING WHEATHEART X SERIES 13 AUGERS X130 74 X130 84 X130 94 118 30787 R2 ...
Страница 122: ...10 APPENDIX WHEATHEART X SERIES 13 AUGERS 10 2 BOLT TORQUE VALUES X130 74 X130 84 X130 94 122 30787 R2 ...
Страница 124: ......