background image

 

 

GENERAL 

The following disclaimers apply to the goods in all circumstances: 

I.

 

The goods must be installed by a certified installer recognized by local authorities, where applicable, and strictly 

in accordance with Westeel’s Installation Instructions  as well as all applicable installation and building codes and 

accepted trade practices.  Without  limiting  the  generality  of  the  foregoing,  proper  foundation  assembly, 

installation  and  use  solely  for  the  purposes  intended  as  specified  in  Westeel’s  published product literature 

is essential.  As well, tank venting for both normal and  emergency situations must be installed properly and kept 

unobstructed always. 

II.

 

The goods must be handled always (including but not limited to shipping, loading and unloading, positioning) 

only  when  empty and  must be  secured always in a manner as specified in the Owners’ Manual.  Any damage 

caused during  handling is not covered by the warranty. 

III.

 

Any  damage  caused  by  foreign  debris  entering  into  the  tanks,  including  but  not  limited to moisture, is not 

covered by the warranty.  It is extremely important for the  owner/user to check for foreign debris inside the tank 

at the time of delivery as well  as before commencing use of the goods and regularly during use of the goods. 

Moisture can  cause  irreparable  damage  to  the  goods  including  but  not  limited  to  a  leak due to microbial 

corrosion.  For further information on moisture monitoring and  removal you may contact: 

 

Steel Tank Institute (STI) 

 

Westeel website 

 

Petroleum Equipment Institute 

IV.

 

Accessories and parts on the goods may not have been manufactured by Westeel  (“third  party  manufactured 

goods”).  Third  party  manufactured  goods  are  not  covered by the warranty.  Warranty terms applicable to 

third-party manufactured  goods are as per the terms published by the  applicable manufacturer.  For further 

information on accessing the website of the applicable manufacturer please contact a  Westeel representative. 

V.

 

Modifications made to the  goods that have  not been approved in  writing by an authorized representative of 

Westeel will result in the warranty being null and void.  This will be the case for any and all damages howsoever 

caused to the goods at any  time after the modification has been made. 

VI.

 

The goods must be maintained and used at all times in a manner consistent with all  Westeel procedures contained 

in the Owners’ Manual as well as prudent, accepted  practice. 

 

Содержание FUEL-VAULT

Страница 1: ...GRAL CONTAINED DUAL WALL TANK OWNERS AND USERS MANUAL READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE INSTALLATION AND USE OF TANK Contact Info www westeel com Toll Free 1 800 665 2099 Email l...

Страница 2: ...Warranty 4 DISCLAIMERS 4 EXTERNAL CORROSION 4 INTERNAL CORROSION 4 GENERAL 5 KNOW YOUR TANK 6 TANK SERIAL NUMBER 6 TANK FUEL COMPATIBILITY 6 TANK MATERIAL 7 DESIGN TEMPERATURE 7 CORROSION ALLOWANCE 8...

Страница 3: ...of which are found to Westeel s satisfaction to be defective Westeel is not responsible for direct indirect special consequential or anyotherdamagesof anykind including personal injury to any individu...

Страница 4: ...ory or otherwise are subsumed and replacedby it and are of no legal effect If any provision of the warranty is held by a court of competent jurisdiction to be void or unenforceable in whole or in part...

Страница 5: ...ner user to check for foreign debris inside the tank at the time of deliveryas well as before commencing use of the goods and regularly during use of the goods Moisture can cause irreparable damage to...

Страница 6: ...Y WARRANTY CLAIMS A PICTURE OF THE ULC NAMEPLATE ALONG WITH THE SERIAL NUMBER OF THE TANK MUST BE PROVIDED TANK FUEL COMPATIBILITY All steel tanks are compatible with all blends of fuels meeting ASTM...

Страница 7: ...RFV 2400 12 GA 12 GA RFV 5000 10 GA 10 GA Table 1 Steel Specification a All gauge sheet ASTM A1011 Commercial Quality b All plates G40 21 44W Pipe Specification ASTM A53 Grade B Schedule 40 Flange Spe...

Страница 8: ...Liquid 1 Cleaned for all contamination 2 Surface Blast to SSPC SP 6 commercial Grade NACE 3 3 Apply D T M Two Component Acrylic Urethane White Gloss paint a 3 0 5 0 Total DFT WCS PC1 2 Powder 1 All Ex...

Страница 9: ...required 2 Order necessary replacement parts immediately to ensure that installation will not be held up by missing parts All parts will be charged for and credit will be issued by the party at fault...

Страница 10: ...nd moving of the materials 5 Tanks shall be carefully handled to prevent damage to the tank coating The use of nylon straps is preferred to prevent damage to the tank coating When using cables or chai...

Страница 11: ...ergo the appropriate inspection prior to relocation 2 The primary tank shall be inspected monthly for the presence of water at the lowest possible points inside the primary tank Remove any water found...

Страница 12: ...Tank Installation and Maintenance decal affixed to the tank...

Страница 13: ...tank designs that are installed in a manner that would allow an accidental overfill of the normal vent pipe This is not to be considered as a condition NOTE ULC tanks must be operated with a minimum...

Страница 14: ...ULC standards and the tank user or installer should refer to electrical codes governing the installation of electrical equipment attached to the tank Use of a dielectric sealant not provided by Westee...

Страница 15: ...3 Care should be taken when placing a tank close to buildings to ensure that snow does not build up on the tank The buildup of snow and ice may also cause failure of the tank emergency and normal ven...

Отзывы: