User Manual
Page 15/16/GB
18.01.96
1
Adjustments of the processor´s electrical processes must only be made by a qualified service technician.
- do the replenishment pumps work properly?
Check this by activating the replenishment
key
a few times, and check that all air has been
expelled from the pumps and hose connec-
tions to the developer and fixer tanks.
Start the processor by activating the sensors
in the insertion slot.
5) Set the required temperature in the
developer, fixer, and dryer sections. Let the
processor run for half an hour.
6) Switch off the processor - let the water out
of the tanks and the replenishment
containers. You should empty each tank
separately to avoid overflow in the floor
drain.
Fill the tanks with the proper chemical
solutions according to the mixing instructions
provided by the chemistry manufacturers.
First, fill the fixer (if any fixer is spilled into the
developer tank - rinse thoroughly with water),
and then the developer. It is important to fill
the tanks fully up to the overflow - if not, the
film may be stained.
7) Fill the replenishment containers with
replenisher for developer and fixer.
According to the mixing instructions.
8) Switch on the processor. Set the
required developing time. Run some
cleaning film through the processor and
check the film transport.
9) Open the valve for rinsing water.
The rinsing water will run when the
sensors on the insertion table is activated.
Содержание Rapiline 135-3
Страница 1: ...RAPILINE 51 RAPILINE 51 SP 1 N agfa ra51 SP chapter1 pm5 Introduction...
Страница 79: ...Manual del usuario P gina 11 16 E 04 03 96...
Страница 101: ...RAPILINE 51 3 RAPILINE 72 3 RAPILINE 95 3 RAPILINE 135 3 I agfa master chap2 gr pm6...
Страница 102: ...30 07 96 2 16 GR 1 2 Agfa 3 4 5 Agfa T V Bauart gepr ft...
Страница 103: ...3 16 GR 30 07 96 2 4 6 7 13 14 16...
Страница 104: ...30 07 96 4 16 GR RC JOG MODE...
Страница 105: ...5 16 GR 30 07 96 x MANUAL REPL 100 cc...
Страница 107: ...7 16 GR 30 07 96 DEV TEMP FIX TEMP DRYER TEMP DEV TIME DEV REPL FIX REPL DEV OXY FIX OXY a b c d e f a f b c d e...
Страница 108: ...30 07 96 8 16 GR HD CHEMISTRY HD CHEMISTRY HD C HD C DEV HD C FIXER TIME SET AUTO START AUTO STOP PANLIGHT INTENSITY...
Страница 109: ...9 16 GR 30 07 96 Dev 35 C 20 s M Dev 35 C 20 s A Dev 35 C 20 s M A AUTO START AUTO STOP 1 2 3 1 2 3 FUNCTION...
Страница 110: ...30 07 96 10 16 GR FIX TEMP 330 C 10 FIX SET 350 C 10 20 sec 16 sec DEV TIME 16 sec DEV SET 16 sec DEV SET 20 sec...
Страница 111: ...11 16 GR 30 07 96 ON OFF OFF STANDBY SOUND PAN LIGHT Panlight OFF DEV TEMP MAN REPL 100cc...
Страница 113: ...13 16 GR 30 07 96 Off line 1 2 3 15 cm 4 5 6 led led PTS PTS min 4 cm...
Страница 114: ...30 07 96 14 16 GR 1 2 3 4 10 cm...
Страница 115: ...15 16 GR 30 07 96 1 5 6 7 8 9...
Страница 116: ...30 07 96 16 16 GR Agfa STANDBY 1 2 3 4 1 35 40 C 2 3 4...
Страница 181: ...RAPILINE 3 Pre installation n agfa master chapter3 pm5...
Страница 185: ...PRE INSTALLATION 3 05 00 RAPILINE 96 03 13...
Страница 191: ...RAPILINE 51 RAPILINE 51 SP SPARE PARTS LIST 4 05 00 96 09 17 3 4 5 10 8 7 6 1 2 9 CASSETTE RAPILINE 51 RAPILINE 51 SP...
Страница 195: ...RAPILINE 51 RAPILINE 51 SP SPARE PARTS LIST 4 09 00 96 09 17 1 2 3 4 5 7 6 8 LIDS RAPILINE 51 RAPILINE 51 SP...
Страница 209: ...RAPILINE 51 RAPILINE 51 SP SPARE PARTS LIST 4 023 00 96 09 17 CONTROL PANEL RAPILINE 51 RAPILINE 51 SP 1...