Section I: Imagesetter
Diagnostics
3-71
6.
If the voltage reading is wrong, check the voltage coming into the solid
state relay (SSR). See Figure 3-3.
a.
Using a DVM, measure the AC voltage across the following two points:
Pin 2 (solid state relay)
At 110 V
⇒
110 V
Pin 1 (volt sensing relay)
At 220 V
⇒
110 V
If the voltage reading is wrong, skip to Step 7.
b.
If the voltage reading is good, check the input side of the SSR. Using a
DVM, measure the DC voltage across the following two points:
Pin 3 (solid state relay)
+24vdc
Pin 4 (solid state relay)
+24vdc
c.
If the DC voltage reading is good, a defective SSR is the probable
cause. Replace the SSR.
If the voltage reading is wrong, go to Step 7.
7.
A bad DC voltage reading may indicate a defective vacuum module PCB or
a problem with the digital signal from the DEC board.
a.
Check the output of the transformer using a DVM to measure the AC
voltage across the following two points:
0V
Outside--Gray Conn
At 110 V
⇒
110 V
115V Outside--Gray Conn
At 220 V
⇒
110 V
8.
A good voltage reading may indicate a defective or miswired volt sensing
relay. Replace the volt sensing relay if the wiring is correct.
9.
If the voltage reading is wrong, check the transformer input. Using a DVM,
measure the AC votage across the following two points:
0V
Outside--Gray Conn
At 110 V
⇒
110 V
115V Outside--Gray Conn
At 220 V
⇒
220 V
10. A good voltage reading may indicate a defective transformer. Replace the
transformer.
11. If the voltage reading is wrong, check the wiring to the transformer.
3.5.1 Volt Sensing Relay Adjustment Procedure
This procedure ensures that systems operating at 220V have vacuum power
stepped down to 110V. which the vacuum pump requires.
To adjust perform the following steps:
1.
Turn the system off and unplug it.
2.
Locate and remove the electronics box at the bottom of the system (see
Section 4.8, Vacuum in Chapter 4, Imagesetter Component Removal/
Replacement Procedure).
Содержание Avantra 36/44
Страница 1: ...The Avantra 36 44 Service Manual Part Number 580078 0002 ...
Страница 24: ...Section I Imagesetter ...
Страница 282: ...Section II Bridge ...
Страница 327: ...Section III Buffer ...
Страница 359: ...Section IV On line Processor ...
Страница 462: ...Avantra 36 44 Service Manual B 2 Spare Parts Avantra 36 44 OLP Parts ...
Страница 464: ...Avantra 36 44 Service Manual B 4 Spare Parts Avantra 36 44 OLP Parts ...
Страница 466: ...Avantra 36 44 Service Manual B 6 Spare Parts Avantra 36 44 OLP Cassette Parts ...
Страница 468: ...Avantra 36 44 Service Manual B 8 Spare Parts Avantra 36 44 OLP Feed Rack Parts ...
Страница 470: ...Avantra 36 44 Service Manual B 10 Spare Parts Avantra 36 44 OLP Tank Parts ...
Страница 472: ...Avantra 36 44 Service Manual B 12 Spare Parts Avantra 36 44 OLP Right Side View Parts ...
Страница 474: ...Avantra 36 44 Service Manual B 14 Spare Parts Avantra 36 44 OLP Control Panel Parts ...
Страница 476: ...Avantra 36 44 Service Manual B 16 Spare Parts Avantra 36 44 OLP Rack Spare Parts ...
Страница 478: ...Avantra 36 44 Service Manual B 18 Spare Parts Avantra 36 44 OLP Dryer Spare Parts 18 ...
Страница 480: ...Avantra 36 44 Service Manual B 20 Spare Parts Electronics upper Spare Parts ...
Страница 482: ...Avantra 36 44 Service Manual B 22 Spare Parts Electronics lower Spare Parts ...
Страница 484: ...C 1 Appendix C Wiring Diagrams ...
Страница 491: ...Section V Crane ...
Страница 521: ...Avantra 36 44 Service Manual I 4 Index ...