Owner’s Manual
6
AGF Manufacturing • Phone: 610-240-4900 • [email protected] •
www.agfmfg.com
External Hard Wire Operation:
1. Remove the four screws on the alarm box and
take the cover off.
2. For external power operation, place the
Voltage Jumper on the two rear pins as
shown in Image 4 (Fig. B).
3. While supporting the bottom of the alarm
enclosure remove the knockout using a
slotted screwdriver and a hammer (place a
clean rag underneath the knockout to prevent
debris from falling onto the circuit board).
4. Install ½”, watertight conduit fitting or cord
grip into the knockout opening and run the
external power source into the alarm housing
as shown in Image 5.
5. Connect external power source to V+ and V-
terminals as shown in Image 6 (Fig. B). Ensure
DC is from a clean power supply and not full-
wave rectified without a capacitor.
6. Replace the cover with the four screws.
TEMPERATURE SENSING FUNCTION
When the Temperature Sensing Function is enabled and water is present in the
auxiliary drain the Model 5100ALBV will not activate the audible and visual alerts
if the ambient temperature is above 45° F. When water is present and the ambient
temperature falls below 45° F the Model 5100ALBV will activate the audible and
visual alerts. The Temperature Sensing Function helps extend battery life and
eliminates unwanted alarm conditions when the threat of freezing is not present.
By default, the Temperature Sensing Function is enable when shipped. The
Model 5100ALBV will not detect water unless the temperature is under 45° F.
See page 7 to disengage Temperature Sensing Function.
+V
-V
COM
TEMPERATURE
JUMPER
VOLTAGE
JUMPER
N.O.
N.C.
Fig. B
VOLTAGE
JUMPER
Image 4
Image 5
Image 6