L.
TO REMOVE THERMOCOUPLE (LHR, RHR AND RHF BURNERS)
1.
Isolate from electric supply.
2.
Proceed as ‘TO REMOVE THE HOTPLATE’.
3.
Undo the nut fixing the thermocouple in place.
4.
Push the thermocouple down and slide to the side to remove from the burner.
5.
Disconnect the other end of the thermcouple cable from the gas valve, this is a push on
electrical terminal.
6.
Re-assemble in reverse order.
M.
TO REMOVE OVEN AND GRILL LINERS - SEE FIG. 33
1.
Remove LH and RH runners (4 screws per runner).
2.
Remove runners and liners.
57
Fig. 33
DESN 512415
Fig. 32
DESN 513531
Содержание SIX-FOUR SERIES - DC6