Vent pipe connection
Fig. 2.7
DESN 516559
The appliance is shown with the oven venting from the RH side.
To gain access remove rear panel (6 screws).
It can also be vented from the LH side, by rotating the copper elbow 180° before fitting the vent pipe.
It can also be vented from the rear using a 45° fitting and exiting through hole in back panel.
Reseal pipe connection with aluminium tape.
When installing an AGA eR7 150-5 which is venting to the left hand side, care must always be taken
to ensure the vent pipe is fully lagged (using insulation provided). Where the vent pipe passes behind
the hot cupboard, ensure that the mains cable is kept away from the hot surface of the vent pipe.
Rear or right hand venting is preferable on installations with a hotcupboard.